No.
Item
Description
Outputs only if the log type information is "BasicLog" and the
category name is other than "AnomalyEvent".
26
Log type information:
■
BasicLog: basic information
■
DetailLog: detailed information
No output when the category name is "AnomalyEvent".
27
Identification of the application. This information is output
when commands are sent from the host.
28
No output.
29
The same information contained in the basic information of
the audit log file, such as interface, task name, function name,
operation name, parameter, result, and serial number. Task
name is output only when a task is registered using Device
Manager - Storage Navigator. No parameter is output if the
operation has no parameters. No serial number is output
when the category name is "AnomalyEvent".
30
The same information contained in the detailed information
of the audit log file.
*A date and time being set on SVP are output as log data. If a failure, such as a SVP
failure and a LAN failure, occurs in the storage system, the data and time may be
output of the accumulated date and time since January 01, 1970.
Syslog
Chapter 1: Failure monitoring
Hitachi Alert Notification Guide for VSP5000 Series
14