7. In the Add Request Authentication Setting window, under User Name, enter a
user name.
You can enter up to 32 alphanumeric characters. The following special characters
are not allowed:
"
,
\
,
;
,
:
,
,
,
*
,
?
,
<
,
>
,
|
,
/
,
^
,
&
, and
%
.
Do not use a space either at the beginning or the end.
8. Under Authentication, select whether to Enable or Disable authentication.
If you select Enable, complete the following steps:
a. For Protocol, select an authentication type.
b. For Password, enter a password.
9. Under Encryption, select whether to Enable or Disable encryption.
Note: If you select Disable for Authentication, Encryption is
automatically disabled.
If you select Enable, complete the following steps:
a. For Protocol, select an encryption type.
b. For Key, enter a key.
c. For Re-enter Key, enter the same key for confirmation.
10. Click OK.
The user you entered is added to the Registered Request Authentication
Settings table.
11. Click Finish.
12. In the Confirm window, enter a name for the task, confirm the settings, and then
click Apply.
Changing request authentication for SNMP v1 and SNMP v2c
This topic describes how to change IP addresses and communities for request
authentication for SNMP v1 and SNMP v2c.
Before you begin
You must have the Storage Administrator (Initial Configuration) role to perform this task.
For more information, see the System Administrator Guide.
Procedure
1. Display the Device Manager - Storage Navigator main window.
2. From the Settings menu, select Environmental Setting > Edit Alert Settings.
3. Select the SNMP tab.
4. Under SNMP Agent, click Enable.
5. Under SNMP Version, select v1 or v2c.
6. Under Registered Request Authentication Settings, select the authentication
setting you want to change, and then click Change.
The Change Request Authentication Setting window opens.
Changing request authentication for SNMP v1 and SNMP v2c
Chapter 4: Setting SNMP
Hitachi Alert Notification Guide for VSP5000 Series
32