LD301 blinks 8 time.
Acceleration defect.
LD301 liting and LD302
blinking 1
—
3 times.
“For distinguish the abnormal
thermistor
, please follow
indication LEVEL.
”
Is the power module normal?
Is the drive circuit normal?
Is the thermistor connector
disconnected?
❈
The problem may be
“forgetting
to connect after servicing
”.
Is the continuity of thermistor normal?
Is the thermistor circuit normal?
Replace the power module.
Replace any defective parts.
Connect the thermistor
.
Replace the thermistor
.
Replace parts in the
thermistor circuit.
Check continuity of pattern and
lead wires according to the
P
.W
.B. and schematic diagrams.
Check continuity of pattern and
lead wires according to the
P
.W
.B. and schematic diagrams.
0305E Pg 90-109
4/1/06, 11:01 AM
98
Summary of Contents for Summit RAC-70YH5
Page 36: ... 35 CIRCUIT DIAGRAM MODEL RAS 70YH5 0305E Pg 35 4 1 06 10 52 AM 1 ...
Page 37: ... 37 CIRCUIT DIAGRAM MODEL RAC 70YH5 0305E Pg 37 4 1 06 10 53 AM 1 ...
Page 39: ... 40 MODEL RAC 70YH5 MAIN P W B 0305E Pg 39 42 4 1 06 10 53 AM 40 ...
Page 40: ... 41 MAIN P W B NF P W B CAPA P W B 0305E Pg 39 42 4 1 06 10 53 AM 41 ...
Page 42: ... 43 51 53 53 55 57 49 29 66 22 0305E Pg 43 4 1 06 10 54 AM 1 ...
Page 86: ... 94 6 Check the main P W B power circuit 0305E Pg 90 109 4 1 06 11 01 AM 94 ...
Page 87: ... 95 CHECKING THE REMOTE CONTROLLER 0305E Pg 90 109 4 1 06 11 01 AM 95 ...
Page 92: ... 100 0305E Pg 90 109 4 1 06 11 01 AM 100 ...
Page 102: ...HITACHI PM NO 0305E Printed in Malaysia RAS 70YH5 RAC 70YH5 0305E cover 4 1 06 12 03 PM 2 ...