– 73 –
(4) During OFF
●
While IC1 is on, the following energy charges the primary windings of the transformer:
Energy=LI
2
/2. Here, L : Primary inductance
I : Current when IC1 is off
This energy discharges to the secondary windings during power off. That is, C707-C710, C718 is
charged according to the turn ratio of each winding.
●
At the start, an overcurrent flows to IC1 because of the charged current at C707-C710, C718.
●
The drain current at IC1 generates a voltage across R716. If it exceeds the IC1 base voltage, it sets the
IC gate voltage to “HI”.
●
R716 limits the gate voltage to prevent excessive collector current from flowing to IC1.
●
This SW power circuit uses a frequency as low as 20kHz, especially at a low load (when both the indoor
and outdoor units stop): This reduces power loss in standby status.
<Reference>
If the power circuit for P.W.B. seems to be faulty:
(1) Make sure that 5V, 12V, 15V, 17V and -5V on the control P.W.B. power voltage are the specified values.
(2) When only the 5V output is low:
REG 1 (regulator) faulty, 5V-0V shorted, output is too high, or REG 1 is abnormal.
(3) When 12V and 5V are abnormal:
The following defects can be considered:
1
Fan, operation, power, rush prevention relay (shorting in relay, etc.)
2
REG 1 (regulator is abnormal), etc.
Shorting on primary circuits.
When shorting occurs in the secondary circuits, there is no abnormality in the primary circuits because
of overcurrent protection.
The voltage rises when an opening occurs in the primary circuits, or the feedback system is abnormal.
(4) When 15V and 17V power supply are abnormal:
D710, D713 or Drive circuit is abnormal.
(5) When all voltage are abnormal:
IC1, R716, may possibly be defective. Also D cable may possibly be reverse connected.
If IC1 is abnormal, be aware that other components, such as the power module, REG (regulator), etc. are
possibly defective.
[When the switching power supply seems to be abnormal, the voltage between IC1 pin
4
(to be measured
at the leads of R701 and R702) and IC1 pin
5
(to be measured at R216 lead) may be between 11 and 16V.
This is because the protection circuit of IC
is operating.]
0305E Pg 57-82
4/1/06, 10:59 AM
73
Summary of Contents for Summit RAC-70YH5
Page 36: ... 35 CIRCUIT DIAGRAM MODEL RAS 70YH5 0305E Pg 35 4 1 06 10 52 AM 1 ...
Page 37: ... 37 CIRCUIT DIAGRAM MODEL RAC 70YH5 0305E Pg 37 4 1 06 10 53 AM 1 ...
Page 39: ... 40 MODEL RAC 70YH5 MAIN P W B 0305E Pg 39 42 4 1 06 10 53 AM 40 ...
Page 40: ... 41 MAIN P W B NF P W B CAPA P W B 0305E Pg 39 42 4 1 06 10 53 AM 41 ...
Page 42: ... 43 51 53 53 55 57 49 29 66 22 0305E Pg 43 4 1 06 10 54 AM 1 ...
Page 86: ... 94 6 Check the main P W B power circuit 0305E Pg 90 109 4 1 06 11 01 AM 94 ...
Page 87: ... 95 CHECKING THE REMOTE CONTROLLER 0305E Pg 90 109 4 1 06 11 01 AM 95 ...
Page 92: ... 100 0305E Pg 90 109 4 1 06 11 01 AM 100 ...
Page 102: ...HITACHI PM NO 0305E Printed in Malaysia RAS 70YH5 RAC 70YH5 0305E cover 4 1 06 12 03 PM 2 ...