– 74 –
6. Rotor magnetic pole position detection circuit
C
A
B
D
E
18
19
20
Microcomputer of outdoor unit
+5V
+12V
C607
IC3
C606
R601
R603
R604
C604
C603
C602
C601
R605
R606
R607
R611
R608
R609
R610
R501
R505
R504
R503
R502
R602
0V
0V
0V
0V
C605
0V
4
5
6
7
3
11
12
8
9
1
2
13
14
10
V
W
U
DC brushless motor
for compressor
lnverter
When the DC brushless motor is rotated, it also operates as power generator, generating reverse electromotive
force according to number of rotations. This reverse electromotive force is voltage-divided by R503 – R505
and R608 – R610, and appears as point
A
voltage. IC3 compares and digitalizes point
A
voltage with point
B
voltage (in which DC voltage (Vd) is voltage-divided by R501, R502 and R611), and inputs this to microcomputer
as position detection signals for points
C
,
D
and
E
. Microcomputer switches inverter using optimum timing
based on position detection signals, in order to control the rotation of the brushless motor.
Fig. 6-1 Rotor magnetic pole position detection circuit
0305E Pg 57-82
4/1/06, 10:59 AM
74
Summary of Contents for Summit RAC-70YH5
Page 36: ... 35 CIRCUIT DIAGRAM MODEL RAS 70YH5 0305E Pg 35 4 1 06 10 52 AM 1 ...
Page 37: ... 37 CIRCUIT DIAGRAM MODEL RAC 70YH5 0305E Pg 37 4 1 06 10 53 AM 1 ...
Page 39: ... 40 MODEL RAC 70YH5 MAIN P W B 0305E Pg 39 42 4 1 06 10 53 AM 40 ...
Page 40: ... 41 MAIN P W B NF P W B CAPA P W B 0305E Pg 39 42 4 1 06 10 53 AM 41 ...
Page 42: ... 43 51 53 53 55 57 49 29 66 22 0305E Pg 43 4 1 06 10 54 AM 1 ...
Page 86: ... 94 6 Check the main P W B power circuit 0305E Pg 90 109 4 1 06 11 01 AM 94 ...
Page 87: ... 95 CHECKING THE REMOTE CONTROLLER 0305E Pg 90 109 4 1 06 11 01 AM 95 ...
Page 92: ... 100 0305E Pg 90 109 4 1 06 11 01 AM 100 ...
Page 102: ...HITACHI PM NO 0305E Printed in Malaysia RAS 70YH5 RAC 70YH5 0305E cover 4 1 06 12 03 PM 2 ...