– 79 –
Table 10-1 Name and Role of each thermistor
Table 10-2 Correspondence between each thermistor’s
resistance and temperature (reference value)
Electric expansion valve
thermistor
DEF thermistor
1.0V
1.7V
3.0V
3.9V
1.0V
1.7V
2.4V
3.1V
4.4V
0.5V
1.3V
2.4V
3.4V
3.6V
3.9V
Outdoor temperature
thermistor
Temperature
Temperature
Temperature
Resistance
Resistance
Resistance
Potential
Potential
Microcomputer
pin potential
OH thermistor
Name
OH thermistor
Compressor head
The thermistors decide the defrost
operation during heating combined
the data of the outside temperature
and its data.
The thermistors detect the
temperatures of the piping to the
indoor units. The temperatures are
used to decide how much the
expansion valve is opened.
Outdoor temperature is used to
decide the various operations of the
air conditioner.
C N 5
DEF thermistor
Heat exchanger
C N 6
Outdoor temperature
thermistor
Outside temperature
C N 7
Electric expansion valve
thermistor
(NARROW PIPE)
Indoor unit
(NARROW PIPE)
C N 8
Electric expansion valve
thermistor
(WIDE PIPE)
Indoor unit
(WIDE PIPE)
Table 10-2 shows the correspondence between
the thermistor’s resistance and the temperature.
They should be used as reference values. The
value, which you measure, may be slightly
difference from that in the table. It depends on
the instrument.
C N 9
Connector No
Measuring Point
Role
When you measure the resistance, pull out the
connector after turning off the power supply.
Pulling out the connector while the power supply
is turned on will cause troubles.
0305E Pg 57-82
4/1/06, 10:59 AM
79
Summary of Contents for Summit RAC-70YH5
Page 36: ... 35 CIRCUIT DIAGRAM MODEL RAS 70YH5 0305E Pg 35 4 1 06 10 52 AM 1 ...
Page 37: ... 37 CIRCUIT DIAGRAM MODEL RAC 70YH5 0305E Pg 37 4 1 06 10 53 AM 1 ...
Page 39: ... 40 MODEL RAC 70YH5 MAIN P W B 0305E Pg 39 42 4 1 06 10 53 AM 40 ...
Page 40: ... 41 MAIN P W B NF P W B CAPA P W B 0305E Pg 39 42 4 1 06 10 53 AM 41 ...
Page 42: ... 43 51 53 53 55 57 49 29 66 22 0305E Pg 43 4 1 06 10 54 AM 1 ...
Page 86: ... 94 6 Check the main P W B power circuit 0305E Pg 90 109 4 1 06 11 01 AM 94 ...
Page 87: ... 95 CHECKING THE REMOTE CONTROLLER 0305E Pg 90 109 4 1 06 11 01 AM 95 ...
Page 92: ... 100 0305E Pg 90 109 4 1 06 11 01 AM 100 ...
Page 102: ...HITACHI PM NO 0305E Printed in Malaysia RAS 70YH5 RAC 70YH5 0305E cover 4 1 06 12 03 PM 2 ...