SJ200
2
Inverter
Appendix B
B–43
The following table lists the holding registers for the “H” Group Motor Constants.
“H” Group Motor Constants
Func.
Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.
H003
Motor capacity
R/W Thirteen selections:
0 .....0.20 kW
1 .....0.37 kW
2 .....0.40 kW
3 .....0.55 kW
4 .....0.75 kW
5 .....1.10 kW
6 .....1.50 kW
7 .....2.2 kW
8 .....3.0 kW
9 .....3.7 kW
10 ...4.0 kW
11 ...5.5 kW
12 ...7.5 kW
1165h
04453
0 to 12
—
H203
Motor capacity, 2nd
setting
R/W
1540h
05440
0 to 12
—
H004
Motor poles setting
R/W Four selections:
2 / 4 / 6 / 8
1166h
04454
2, 4, 6,
8
1 pole
H204
Motor poles setting, 2nd
motor
R/W
1541h
05441
2, 4, 6,
8
1 pole
H006
Motor stabilization
constant
R/W Motor constant (factory set),
range is 0 to 255
1168h
04456 0 to 255
1
H206
Motor stabilization
constant, 2nd motor
R/W
1543h
05443 0 to 255
1
H007
Motor voltage select
R/W Two selections, option codes:
00 ...200V
01 ...400V
1169h
04457
0, 1
—
H207
Motor voltage select,
2nd motor
R/W
1544h
05444
0, 1
—