“B” Group: Fine Tuning Functions
Configur
ing
Dr
iv
e P
a
ra
m
e
ters
3–42
B090: Dynamic braking usage ratio –
This parameter limits the amount of time the
inverter can use the dynamic braking accessory device without entering the Trip Mode.
Please refer to
“Dynamic Braking” on page 5–5
for more information on dynamic
braking accessories.
B130/B131:
Over-voltage LADSTOP Enable / Over-voltage LADSTOP Level –
The over-
voltage LADSTOP function monitors the DC bus voltage and actively changes the
output frequency profile to maintain the DC bus voltage within settable limits. Although
“LAD” refers to “linear acceleration / deceleration,” the inverter only “STOPs” the
deceleration slope so that regenerative voltage will not cause the DC bus to rise enough
to cause an over-voltage trip event. Note that acceleration is not affected.
“B” Function
Run
Mode
Edit
Lo Hi
Defaults
Func.
Code
Name /
SRW Display
Description
–FE(F)
(EU)
–FU
(USA)
Units
B088 Restart mode after FRS
Selects how the inverter
resumes operation when the
free-run stop (FRS) is
cancelled, two options:
00... Restart from 0Hz
01... Restart from frequency
detected from real speed of
motor (frequency matching)
✘ ✔
00
00
—
RUN FRS ZST
B090 Dynamic braking usage
ratio
Selects the rate of use (in %) of
the regenerative braking
resistor per 100 sec. intervals,
range is 0.0 to 100.0%
0% . Dynamic braking disabled
>0% Enabled, per value
✘ ✔
0.0
0.0
%
BRD %ED 0000.0%
B091 Stop mode selection
Selects how the inverter stops
the motor, two option codes:
00... DEC (decelerate and stop)
01... FRS (free run to stop)
✘ ✘
00
00
—
STP Slct DEC
B092 Cooling fan control
Selects when the fan is ON per
inverter operation, two options:
00... Fan is always ON
01... Fan is ON during run,
OFF during stop (5 min.
delay from ON to OFF)
02... Fan is temperature-
controlled
✘ ✘
00
00
—
FAN-CTRL OFF
B095 Dynamic braking
control
Three option codes:
00... Disable
01... Enable during RUN only
02... Enable always
✘ ✔
00
00
—
BRD Slct OFF
B096 Dynamic braking
activation level
Range is:
330 to 380V (200V class),
660 to 760V (400V class)
✘ ✔
360/
720
360/
720
—
BRD LVL 00360V