3–53
Output Function Summary Table –
This table shows all eleven functions for the
logical outputs (terminals [11], [12]) at a glance. Detailed descriptions of these
functions, related parameters and settings, and example wiring diagrams are in
“Using
Intelligent Output Terminals” on page 4–36
.
Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
00
RUN
Run Signal
ON
when inverter is in Run Mode
OFF
when inverter is in Stop Mode
01
FA1
Frequency Arrival
Type 1 – Constant
Speed
ON
when output to motor is at the set frequency
OFF
when output to motor is OFF, or in any accelera-
tion or deceleration ramp
02
FA2
Frequency Arrival
Type 2 – Over-
frequency
ON
when output to motor is at or above the FA2
threshold (C042) during accel
OFF
when output to motor is below the FA2 threshold
(C043) during decel
03
OL
Overload Advance
Notice Signal
ON
when output current is more than the set thresh-
old for the overload signal
OFF
when output current is less than the set threshold
for the overload signal
04
OD
Output Deviation for
PID Control
ON
when PID error is more than the set threshold for
the deviation signal
OFF
when PID error is less than the set threshold for
the deviation signal
05
AL
Alarm Signal
ON
when an alarm signal has occurred and has not
been cleared
OFF
when no alarm has occurred since the last
clearing of alarm(s)
06
Dc
Analog Input
Disconnect Detect
ON
when the [O] input value < B082 setting (signal
loss detected), or the [OI] input current < 4mA
OFF
when no signal loss is detected
07
FBV
PID Second Stage
Output
ON
Transitions to ON when the inverter is in RUN
Mode and the PID Process Variable (PV) is less
than the Feedback Low Limit (C053)
OFF
Transitions to OFF the PID Feedback Value (PV)
exceeds the PID High Limit (C052), and transi-
tions to OFF when the inverter goes from Run
Mode to Stop Mode.
08
NDc
ModBus Network
Detection Signal
ON
when the communications watchdog timer
(period specified by C077) has timed out
OFF
when the communications watchdog timer is
satisfied by regular communications activity