ModBus Data Listing
Appendix B
B–32
A103
[OI]–[L] input active
range start current
R/W The starting point for the
current input range.
Range is 0. to 100.%
1083h
04227
0 to 100
1 %
A104
[OI]–[L] input active
range end current
R/W The ending point for the
current input range.
Range is 0. to 100.%
1084h
04228
0 to 100
1 %
A105
[OI]–[L] input start
frequency enable
R/W Two options:
00 .. Use A101 start value
01 .. Use 0Hz
1085h
04229
0, 1
—
A141
A input select for calcu-
late function
R/W Five options:
00 .. Digital operator
01 .. Keypad potentiometer
02 .. [O] input
03 .. [OI] input
04 .. Network variable
108Eh
04238
0 to 4
—
A142
B input select for calcu-
late function
R/W Five options:
00 .. Digital operator
01 .. Keypad potentiometer
02 .. [O] input
03 .. [OI] input
04 .. Network variable
108Fh
04239
0 to 4
—
A143
Calculation symbol
R/W Calculates a value based on
the A input source (A141
selects) and the B input source
(A142 selects). Three options:
00 .. ADD (A input + B
input)
01 .. SUB (A input – B input)
02 .. MUL (A input x B input)
1090h
04240
0 1, 2
—
A145
ADD frequency
R/W An offset value that is applied
to the output frequency when
the [ADD] terminal is ON.
Range is 0.0 to 400.0 Hz
1091h
04241
0 to 4000
0.1 Hz
A146
ADD direction select
R/W Two options:
00 .. Plus (adds A145 value to
the output frequency setting)
01 .. Minus (subtracts A145
value from the output
frequency setting)
1093h
04243
0, 1
—
A151
Pot. input active range
start frequency
R/W The output frequency corre-
sponding to the potentiometer
range starting point,
range is 0.0 to 400.0
1095h
4245
0 to 4000
0.1 Hz
Holding Registers for “A” Group Standard Functions
Func.
Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.
Summary of Contents for SJ2002 Series
Page 2: ......
Page 46: ......
Page 214: ......
Page 231: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 282: ......
Page 299: ...SJ2002 Inverter Appendix D D 5 L1 L2 L3 PE SJ2002 inverter with book type filter M 3 ...