93
6.6 Power Supply Control
This section describes the power supply control functions. Table 6.6 summarizes the power supply controller
registers. In addition, refer to 6.6.1 to 6.6.3 for details of each register.
(1) Solution Engine2 is turned ON or OFF.
(2) When Solution Engine2 is OFF, it is turned ON if the power-on switch is pressed for 2sec or more.
(3) Solution Engine2 can be turned OFF from the SH7760.
(4) If the DIP switch (SW7) is se to ON, Solution Engine2 is also turned ON at the same time the power supply
controller is turned ON.
Table 6.6 Power Control Registers
Register
Abbreviation
Address
R/W
Size
Remarks
System power control register 1
SPOWCR1
0x0070
R/W
1 byte
System power control register 2
SPOWCR2
0x0071
R/W
1 byte