10
6
6.12 Electronic Volume Control
This section describes the electronic volume control functions. Table 6.12 summarizes the electronic volume
control registers. For details of each register, refer to 6.12.1 and 6.12.2.
(1)
An electronic volume value can be set.
An electronic volume value can be set within a range from 0x00 (minimum sound volume) to 0xFF
(maximum sound volume).
(2)
Two electronic volume values can be set.
An electronic volume value can be set for the right or left speaker.
Table 6.12 Electronic Volume Control Registers
Register
Abbreviation
Address
R/W
Size
Electronic volume data register for the right
speaker
EVRDR
0x00D0
R/W
1 byte
Electronic volume data register for the left
speaker
EVLDR
0x00D1
R/W
1 byte
6.12.1 Electronic Volume Data Register for the Right Speaker (EVRDR)
Address: 0x00D0 Initial value: 0x00
D7
D6
D5
D4
D3
D2
D1
D0
EVRDR_D7
EVRDR_D6
EVRDR_D5
EVRDR_D4
EVRDR_D3
EVRDR_D2
EVRDR_D1
EVRDR_D0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Values from 0x00 to 0xFF can be set.
6.12.2 Electronic Volume Data Register for the Left Speaker (EVLDR)
Address: 0x00D1 Initial value: 0x00
D7
D6
D5
D4
D3
D2
D1
D0
EVLRD_D7
EVLRD_D6
EVLDR_D5
EVLDR_D4
EVLDR_D3
EVLDR_D2
EVLDR_D1
EVLDR_D0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Values from 0x00 to 0xFF can be set.
Summary of Contents for SH7760 Solution Engine2