99
6.10.1 Infrared Remote Control Register (IRRCR)
Address; 0x00B0 Initial value: 0x00
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
TDIE
RDIE
FORMAT
START
R
R
R
R
R/W
R/W
R/W
R/W
(1) START
START bit
Setting
0
Infrared remote control is disabled. (Initial value)
1
Infrared remote control is enabled to start data transmission/reception.
(2) FORMAT
FORMAT bit
Setting
0
The NEC format is set, (Initial value)
1
The Home Appliance Manufacturer’s Association format is set
(3) RDIE
RDIE bit
Setting
0
An interrupt is disabled upon completion of receiving a frame of
infrared remote control signal. (Initial value).
1
An interrupt is enabled upon completion of receiving a frame of
infrared remote control signal.
(4) TDIE
TDIE bit
Setting
0
An interrupt is disabled upon completion of transmitting a frame of
infrared remote control signal. (Initial value)
1
An interrupt is enabled upon completion of transmitting a frame of
infrared remote control signal.