– 9 –
SIX ROOMS SYSTEM MULTI R.A.C.
RAM-130QH5
INDOOR UNITS COMBINATIONS TO BE ABLE TO INSTALL
Four or more indoor units can be installed with one outdoor unit.
And total nominal cooling capacity should not be more than 18.0kW
INDOOR UNIT
MODEL
NOMINAL
COOLING
CAPACITY
(kW)
CAPACITY (kW)
at one unit operation
SUITABLE ROOM SIZE (m
2
)
at one unit operation
COOLING
HEATING
COOLING
HEATING
RAK-25NH5
RAK-25NH6
2.5
1.00 - 2.80
1.10 - 4.70
11 - 17
14 - 18
RAF-25NH5
2.5
1.00 - 2.80
1.10 - 4.70
11 - 17
14 - 18
RAK-18NH5
RAK-18NH6
1.8
1.00 - 2.50
1.10 - 3.20
8 - 12
9 - 11
RAD-25NH5
RAD-25NH7
2.5
1.00 - 2.80
1.10 - 4.70
11 - 17
14 - 18
RAI-25NH5
2.5
1.00 - 2.80
1.10 - 4.70
11 - 17
14 - 18
RAK-35NH5
RAK-35NH6
3.5
1.00 - 3.90
1.10 - 5.80
16 - 24
17 - 22
RAF-35NH5
3.5
1.00 - 3.90
1.10 - 5.80
16 - 24
17 - 22
RAD-35NH5
RAD-35NH7
3.5
1.00 - 3.90
1.10 - 5.80
16 - 24
17 - 22
RAI-35NH5
3.5
1.00 - 3.90
1.10 - 5.80
16 - 24
17 - 22
RAK-50NH5
RAK-50NH6
5.0
1.00 - 5.60
1.10 - 7.20
23 - 34
23 - 29
RAF-50NH5
5.0
1.00 - 5.60
1.10 - 7.20
23 - 34
23 - 29
RAI-50NH5
5.0
1.00 - 5.60
1.10 - 7.20
23 - 34
23 - 29
Be sure to connect four or more indoor units to this outdoor unit. If not, condensed water may drop, resulting in
trouble.
At least four indoor unit to be connected to the outdoor unit which means two indoor units for each cycle (upper
and lower). Anyway indoor unit 3 and 6 must be connected.
RAD-50NH7
5.0
1.00 - 5.60
1.10 - 7.50
23 - 34
23 - 29
Summary of Contents for RAM-130QH5
Page 10: ... 11 SIX ROOM SYSTEM MULTI R A C RAM 130QH5 CONNECTING POSISION TO BE ABLE TO INSTALL ...
Page 20: ... 22 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 130QH5 ...
Page 25: ... 29 6V01 ...
Page 26: ... 31 ...
Page 28: ... 35 ...
Page 33: ... 41 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 34: ... 43 ...
Page 35: ... 45 ...
Page 36: ... 47 ...
Page 37: ... 49 ...
Page 47: ... 59 5A ...
Page 54: ... 66 ...
Page 55: ... 67 5 Reversing valve control circuit Fig 5 1 ...
Page 77: ... 92 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 78: ... 93 ...
Page 79: ... 94 ...
Page 83: ... 98 ...
Page 84: ...HITACHI PM NO 0000 Printed in Malaysia RAM 130QH5 ...