– 88 –
TROUBLE SHOOTING
Model
RAM-55QH5
RAM-65QH5
PRECAUTIONS FOR CHECKING
1. Remember that the
0V line is biased to
162V in reference to
the ground level.
2. Also note that it takes
about 10 minutes
until the voltage fall
after the power switch
is turned off.
Across a – b (0V line)....................
Across a – ground..........................
Across b (0V line)– ground............
approx 360V
approx 155-170V
approx 155-170V
When using an
oscilloscope, never
ground it. Don't forget
that high voltages as
noted above may
apply to the
oscilloscope.
DANGER
DANGER
Power source
1 ø 220-240V, 50Hz
(B)
(A)
DANGER !
Don't install
the ground line
Always keep your
hands and metallic
things away the
enclosure of the
scilloscop
outdoor unit 1 P.W.B
outdoor unit 2 P.W.B