– 16 –
Screw
Insulating plate
Cord band
Connecting cord
Connection of the connecting cords and power cord. (Outdoor unit)
RAM-130QH5
WARNING
!
Connecting cord should be connected according to Fig.1, that the Indoor unit No. shall match with terminal board No.
of Outdoor unit.
Be sure to fix the connecting cord with the band as shown below. Otherwise water leakage causes short circuit or faults.
•
•
•
CAUTION
!
•
If earth line cannot be taken from
the power supply connection, use
the optional grounding rod to do
earthing.
Type of grounding rod
SP-EB-2
Length
900mm
WARNING
!
Connection of the power cord and connecting
cord
Securely screw in the power cord
and connecting cord so that it will not
get loose or disconnect.
Tightening torque reference value:
1.2 to 1.6 N•m (12 to 16 kgf•cm)
Excessive tightening may damage
the interior of the cord requiring
replacement.
Power cord and
Connecting cord
CAUTION
!
•
To prevent a connection error, connecting cords
should be bundled and taped to each respective
pipe. If connecting cords are mixed with other indoor
units, a refrigeration cycle abnormality may occur,
causing dripping.
When putting two connecting cords through the band.
•
Hold the handle of the side cover, slide down and take off the corner hook, then pull. Reverse these steps when installing.
WARNING
!
•
•
Leave some space in the connecting cord for maintenance purpose
and be sure to secure it with the cord band.
Secure the connecting cord along the coated part
of the wire using the cord band. Do not exert
pressure on the wire as this may cause
overheating or fire.
Screw for ground, earth screw
Outdoor Unit
Wiring Pattern
Indoor Unit
Power cord
C
D
C1 D1
Indoor unit No. 1
Screw for ground, earth screw
Screw for ground, earth screw
For Indoor unit No. 1
Terminal board
Terminal board
Connecting cord
Ø1.6 or 2.0
Green-and-
Yellow
C
D
C2 D2
Indoor unit No. 2
Screw for ground, earth screw
Screw for ground, earth screw
For Indoor unit No. 2
Terminal board
Terminal board
Green-and-
Yellow
C
D
C3 D3
L
N
Indoor unit No. 3
Screw for ground, earth screw
Screw for ground,
earth screw
For Indoor unit No. 3
Terminal board
Terminal board
Terminal board
Green-and-
Yellow
Green-and-Yellow
Screw for ground, earth screw
C
D
C4 D4
Indoor unit No. 4
Screw for ground, earth screw
Screw for ground, earth screw
For Indoor unit No. 4
Terminal board
Terminal board
Green-and-
Yellow
C
D
C5 D5
Indoor unit No. 5
Screw for ground, earth screw
Screw for ground, earth screw
For Indoor unit No. 5
Terminal board
Terminal board
Green-and-
Yellow
C
D
C6 D6
Indoor unit No. 6
Screw for ground, earth screw
For Indoor unit No. 6
Terminal board
Terminal board
Connecting cord
Ø1.6 or 2.0
Green-and-Yellow
Grounding rod (optional)
Earth line and grounding rod are not supplied.
Please use optional items below.
( )
INDOOR 1
C1
D1
C2
D2
INDOOR 2
C3
D3
INDOOR 3
After remove the
screw and cover,
put the connecting
cords and fix
the cover with
screw.
After remove the
screw and cover,
put the connecting
cords and fix
the cover with
screw.
Earth line
AC 220V~240V ONLY
L N
INDOOR 4
C4
D4
C5
D5
INDOOR 5
C6
D6
INDOOR 6
Connect the
earth cord
Summary of Contents for RAM-130QH5
Page 10: ... 11 SIX ROOM SYSTEM MULTI R A C RAM 130QH5 CONNECTING POSISION TO BE ABLE TO INSTALL ...
Page 20: ... 22 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 130QH5 ...
Page 25: ... 29 6V01 ...
Page 26: ... 31 ...
Page 28: ... 35 ...
Page 33: ... 41 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 34: ... 43 ...
Page 35: ... 45 ...
Page 36: ... 47 ...
Page 37: ... 49 ...
Page 47: ... 59 5A ...
Page 54: ... 66 ...
Page 55: ... 67 5 Reversing valve control circuit Fig 5 1 ...
Page 77: ... 92 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 78: ... 93 ...
Page 79: ... 94 ...
Page 83: ... 98 ...
Page 84: ...HITACHI PM NO 0000 Printed in Malaysia RAM 130QH5 ...