– 39 –
MODEL
PROM
NO.
0A2
RTOTSA
˚C
2.00
˚C
2.00
144
SHIFTW_M
˚C
5.00
˚C
5.00
145
SFTSZW_M
˚C
5.00
˚C
5.00
146
SHIFTC_M
˚C
1.66
˚C
1.66
147
SHIFTD_M
˚C
1.66
˚C
1.66
148
CLMXTP_M
˚C
30.00
˚C
30.00
149
YNEOF_M
˚C
20.00
˚C
20.00
14E
TEION_M
˚C
0.00
˚C
0.00
14F
TEIOF_M
˚C
9.00
˚C
9.00
157
CMNLMT_M
min
-1
0
min
-1
0
178
FWSS_M
V
13.1
V
13.1
179
FWSOY_M
V
17.6
V
17.6
17A
FWS_M
V
20.3
V
20.3
17B
FWKAF_M
V
22.9
V
22.9
17C
FWL_M
V
22.9
V
22.9
17D
FWAH_M
V
27.9
V
27.9
17E
FWH_M
V
28.3
V
28.3
17F
FWHH_M
V
28.3
V
28.3
180
FCSOY_M
V
18.0
V
18.0
181
FCS_M
V
20.5
V
20.5
182
FCL_M
V
25.0
V
25.0
183
FCAH_M
V
27.9
V
27.9
184
FCH_M
V
27.9
V
27.9
185
FCHH_M
V
27.9
V
27.9
186
FDOY_M
V
18.0
V
18.0
187
FDS1_M
V
20.5
V
20.5
188
FDS2_M
FWSOY_M
Sleep
FWSS_M
Ultra Lo
Label name
Fan speed mode
Label name
Operation mode
Heating operation
Operation
mode
Heating
operation
Cooling
operation
Dehumidifying
operation
Table 1 Fan speed by mode
Table 2 Room temperature shift value
FWS_M
Lo
Hi
Hi
Hi
Hi
FWKAF_M
Overload
FCSOY_M
Sleep
FWHH_M
Ultra Hi
FCS_M
Lo
FCL_M
Med
FDOY_M
Sleep
FCHH_M
Ultra Hi
FDS1_M
Lo 1
FDS2_M
Lo 2
FWL_M
Med
FWAH_M
Set fan speed "AUTO"
FWH_M
Set fan speed "HI"
FCAH_M
Set fan speed "AUTO"
FCH_M
Set fan speed "HI"
SHIFTW_M
Fan speed "AUTO, Hi, Med"
SFTSZW_M
Fan speed "Lo, Sleep"
SHIFTC_M
Cooling operation
SHIFTD_M
Dehumidifying operation
V
20.5
V
20.5
120
WMAX_M
min
-1
5300
min
-1
5000
121
WMAX2_M
min
-1
5300
min
-1
5000
122
WSTD_M
min
-1
4000
min
-1
4000
123
WJKMAX_M
min
-1
3600
min
-1
3700
124
WBEMAX_M
min
-1
3200
min
-1
3500
127
CMAX_M
min
-1
3300
min
-1
3300
128
CMAX2_M
min
-1
3300
min
-1
3300
129
CSTD_M
min
-1
3000
min
-1
3150
12A
CKYMAX_M
min
-1
2500
min
-1
2800
12B
CJKMAX_M
min
-1
2300
min
-1
2750
12C
CBEMAX_M
min
-1
1900
min
-1
2500
12F
SDMAX_M
min
-1
2050
min
-1
2400
130
SDRPM_M
min
-1
1800
min
-1
2000
138
WMIN_M
min
-1
800
min
-1
800
139
CMINHI_M
min
-1
800
min
-1
800
13A
CMIN_M
min
-1
1000
min
-1
1200
13B
DMIN_M
min
-1
1000
min
-1
1200
13C
PKOU_M
min
-1
500
min
-1
500
13E
FZZYTM_M
min.
3
min.
3
13D
FZZY_GN_M
1.0
1.0
REQUIRED VALUE
OF UNIT SIDE
REQUIRED VALUE
OF UNIT SIDE
LABEL NAME
RAD-25NH5
RAD-35NH5
Summary of Contents for RAM-130QH5
Page 10: ... 11 SIX ROOM SYSTEM MULTI R A C RAM 130QH5 CONNECTING POSISION TO BE ABLE TO INSTALL ...
Page 20: ... 22 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 130QH5 ...
Page 25: ... 29 6V01 ...
Page 26: ... 31 ...
Page 28: ... 35 ...
Page 33: ... 41 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 34: ... 43 ...
Page 35: ... 45 ...
Page 36: ... 47 ...
Page 37: ... 49 ...
Page 47: ... 59 5A ...
Page 54: ... 66 ...
Page 55: ... 67 5 Reversing valve control circuit Fig 5 1 ...
Page 77: ... 92 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 78: ... 93 ...
Page 79: ... 94 ...
Page 83: ... 98 ...
Page 84: ...HITACHI PM NO 0000 Printed in Malaysia RAM 130QH5 ...