BLOCK DIAGRAM
Outdoor
micro computer (6V01)
Magnetic relay
Inrush current
protection relay
M
Rotor position
detector
Overload current
detector
SPM driver
Overheat
thermistor
Defrost
thermistor
Outdoor temp
thermistor
Indoor/Outdoor
Interface 1
Indoor/Outdoor
Interface 2
Indoor/Outdoor
Interface 3
Switching power supply 2
Switching power supply 1
Reset circuit
Clock circuit
Multiplexer
Expansion valve
thermistor 3
Expansion valve
thermistor 1
Expansion valve
thermistor 2
Expansion valve 1
Expansion valve 2
Expansion valve 3
Expansion valve
drive circuit
Reversing valve
drive circuit
Reversing valve
EEPROM
Fan motor
drive circuit
M
A
B
compressor
fan motor
Indoor unit 1
Indoor unit 2
Indoor unit 3
C1/D1
C2/D2
C3/D3
single phase 50Hz, 220-240V
Outdoor Unit 1
System
Power
Module
Outdoor
micro computer (6V01)
Magnetic relay
Inrush current
protection relay
M
Rotor position
detector
Overload current
detector
SPM driver
Overheat
thermistor
Defrost
thermistor
Outdoor temp
thermistor
Indoor/Outdoor
Interface 4
Indoor/Outdoor
Interface 5
Indoor/Outdoor
Interface 6
Switching power supply 2
Switching power supply 1
Reset circuit
Clock circuit
Multiplexer
Expansion valve
thermistor 6
Expansion valve
thermistor 4
Expansion valve
thermistor 5
Expansion valve 4
Expansion valve 5
Expansion valve 6
Expansion valve
drive circuit
Reversing valve
drive circuit
Reversing valve
EEPROM
Fan motor
drive circuit
M
compressor
fan motor
Indoor unit 4
Indoor unit 5
Indoor unit 6
C4/D4
C5/D5
C6/D6
Outdoor Unit 2
System
Power
Module
L
N
– 33 –
Summary of Contents for RAM-130QH5
Page 10: ... 11 SIX ROOM SYSTEM MULTI R A C RAM 130QH5 CONNECTING POSISION TO BE ABLE TO INSTALL ...
Page 20: ... 22 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 130QH5 ...
Page 25: ... 29 6V01 ...
Page 26: ... 31 ...
Page 28: ... 35 ...
Page 33: ... 41 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 34: ... 43 ...
Page 35: ... 45 ...
Page 36: ... 47 ...
Page 37: ... 49 ...
Page 47: ... 59 5A ...
Page 54: ... 66 ...
Page 55: ... 67 5 Reversing valve control circuit Fig 5 1 ...
Page 77: ... 92 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 78: ... 93 ...
Page 79: ... 94 ...
Page 83: ... 98 ...
Page 84: ...HITACHI PM NO 0000 Printed in Malaysia RAM 130QH5 ...