5.5.1 Driving with the standard panel 

 

RUN/STOP/RESET key on the standard operation panel is effective regardless of the setting of the driving order method(A002).

 

Thus, the following 

operation method (1) to (3) is possible without an option if it is an initial value. 

 

(1)Method to perform driving in RUN/STOP/RESET key and perform frequency setting in Multispeed select 

 

This is the operation method using Run command is given by "RUN/STOP/RESET key" 

& Frequency setting is given by Fixed value such as 20/40/60Hz, Accel&Decel time is 

10  seconds.  If  you  don't  need  to  change  parameters  such  as  Accel&Decel  time,  the 

optional  Operator  is  not  required.)  To  use  the  set  Freq.  setting,  use  the  Multi-speed   

default frequency setting (1=60Hz),(2=40Hz),(3=20Hz). 

 

Setup 

 

Function Name 

Code 

Data 

Note 

Input [3] function 

C003 

02(CF1) 

Default 

Input [4] function 

C004 

03(CF2) 

The initial value of Acceleration/ Deceleration time is 10sec. 

Please change the following parameters as needed. 

Function Name 

Code 

Setting Range 

Note 

Acceleration time 

F002 

0.00 to 3600sec. 

Default

10 sec. 

Deceleration time 

F003 

0.00 to 3600sec. 

Default

10 sec. 

 One of the following is required when changing parameters on NE-S1 series inverters. 

  Dedicated operator (NES1-OP)

 

② 

Digital operator   

    5-line LCD operator 

④ 

Modbus   

⑤ 

PC programming tool (ProDriveNext) 

 

(2) Method to perform driving in RUN/STOP/RESET key and perform frequency setting in speed potentiometer 

 

This is the operation method using Run command is given by "RUN/STOP/RESET key" & Frequency setting is given by analog input such as 

O-L voltage, Accel&Decel time is 10 seconds. If you don't need to change parameter such as Accel&Decel time, the optional Operator is not required.) 

Below diagram is to set the external Freq. setting connecting H-O-L volume to supply O-L voltage. 

 

Setup 

 

Function Name 

Code 

Data 

Note 

Frequency source 

A001 

01(Control circuit terminals) 

Default 

The initial value of Acceleration/ Deceleration time is 10sec. 

Please change the following parameters as needed. 

 

Function Name 

Code 

Setting Range 

Note 

Acceleration time 

F002 

0.00 to 3600 sec. 

default

10 sec. 

Deceleration time 

F003 

0.00 to 3600 sec. 

default

10 sec. 

 One of the following is required when changing default parameters on NE-S1 series 

inverters. 

  Dedicated operator (NES1-OP)

 

② 

Digital operator   

    5-line LCD operator 

④ 

Modbus   

⑤ 

PC programming tool (ProDriveNext) 

 

(3) Method to perform driving in FW/RV teraminal and perform frequency setting in volume resistor 

 

This is the operation method using Run command is given by intelligent input terminal such as FW(RV) function & Frequency setting is given by 

analog input such as O-L voltage.    If you don't need to change such as Accel&Decel time, optional Operator is not required.) Below diagram is to set 

the external Freq. setting connecting H-O-L volume to supply O-L voltage. 

 

Setup 

 

Function Name 

Code 

Data 

Note 

Frequency source 

A001 

01(Control circuit terminals) 

Default 

Run command source 

A002 

01(Control circuit terminals) 

Default

 

Input [1] function 

C001 

00(FW) 

Default

 

Input [2] function 

C002 

01(RV) 

The initial value of Acceleration/ Deceleration time    is 10sec. 
Please change the following parameters as needed. 

 

Function Name 

Code 

Setting Range 

Note 

Acceleration time 

F002 

0.00 to 3600 sec. 

Default

10 sec. 

Deceleration time 

F003 

0.00 to 3600 sec. 

Default

10 sec. 

 One of the following is required when changing default parameters on NE-S1 series 

inverters. 

  Dedicated operator (NES1-OP)

 

② 

Digital operator   

    5-line LCD operator 

④ 

Modbus   

⑤ 

PC programming tool (ProDriveNext)

 

Example of use(default) 

 

Intelligent input 

terminal [3] 

Intelligent input 

terminal [4] 

60Hz order 

OFF 

ON 

40Hz order 

ON 

OFF 

20Hz order 

ON 

ON 

 

Control circuit terminals wiring

 

P24 

PLC 

CF1 

CF2 

… 

Note)

 

 

The  above  is  a  method  to  perform  analog 

input(O/OI) by voltage input.

 

It is necessary for 

SW6  on  the  board  to  be  set  for  voltage 
input(default).   

 

 

P9 

 

Control circuit terminals wiring

 

P24 

PLC 

O/OI 

FW 

RV 

Frequency setting 
resistor 

 

P24 

PLC 

O/OI 

Frequency setting 
resistor 

Note)

 

 

The  above  is  a  method  to  perform  analog 

input(O/OI) by voltage input.

 

It is necessary for 

SW6  on  the  board  to  be  set  for  voltage 
input(default).   

 

 

P9 

 

Control circuit terminals wiring

 

Summary of Contents for NES1-OP

Page 1: ...nd QRG Quick Reference Guide and understand perfectly how to handle properly and the safety cautions of the product before operation for safety and proper usage Note that this Manual is intended for each product and should be delivered to the end user of the inverter NT341BX Many of the drawings in the Instruction Manual show the inverter with covers and or parts blocking your view being removed D...

Page 2: ...cility can be operated Otherwise you run the risk of injury or damage to the machine controlled by the inverter Do not touch the heat sink which heats up during the inverter operation Otherwise you run the risk of burn injury The inverter allows you to easily control the speed of motor or machine operations Before operating the inverter confirm the capacity and ratings of the motor or machine cont...

Page 3: ...tection required at end application h Use 60 75ºC CU wire only i Tightening torque and wire range as shown in the table below Model No Required Torque N m Wire Range AWG NES1 002S 0 8 1 0 16 14 NES1 004S 0 8 1 0 16 14 NES1 007S 1 8 14 12 NES1 015S 1 8 12 10 NES1 022S 1 8 10 NES1 002L 0 8 1 0 16 14 NES1 004L 0 8 1 0 16 14 NES1 007L 0 8 1 0 16 14 NES1 015L 1 8 14 NES1 022L 1 8 12 j Distribution fuse...

Page 4: ... name of the inverter 2 Manufacturing number 3 When you bought the product 4 Contents of your inquiry Damaged portion and condition and else 1 4 Warranty Terms The warranty period under normal installation and handling conditions shall be two 2 years from the date of manufacture or one 1 year from the date of installation whichever occurs first The warranty shall cover the repair or replacement at...

Page 5: ...lease be sure to check that this lamp is turned OFF after waiting 10 minutes of power OFF Note1 Refer to page 13 for the description of the display and key operation Note 2 Position of charge lamp depends on the model Refer to page 11 for the details Note 3 Pay attention when operating by PC via RS422 RS485 port as the operation can also be done from the panel of the inverter Note 4 Be sure to tur...

Page 6: ...g is generated inside the inverter electronic parts are short circuited each other to cause a failure Also please avoid installing it in direct sunlight Caution for installation environment Please avoid installing the inverter in such places where dust corrosive gas explosive gas flammable gas mist of grinding fluid or salt pollution etc exists Invasion of dust dirt etc into the inverter may cause...

Page 7: ...C software ProDriveNext See above for the position of the window Be sure to make window after removing the front cover There are cutouts at the window so it can be removed easily by pressing up side and bottom side of the window alternatively The window cannot be restored if it is once opened Please use commercially supplied RJ45 connector cap or the like if necessary 3 How to attach Press the fro...

Page 8: ... G Earth terminal To make grounding Be sure to make this grounding to avoid electric shock and for improving the EMC performance The terminal is located on the heatsink Intelligent inputs 7 terminals 0 10VDC 10bit PLC P24 DC24V L P H O OI Category D grounding 200V class DC10V 5 2 1 3 4 Intelligent input terminal 11 CM2 Relay contacts AL0 AL1 AL2 L DC10V 10mA Max 4 7kΩ 4 7kΩ L FM L Pulse train outp...

Page 9: ...gent output terminals One function from 28 available functions can be assigned Refer to section 7 3 of QRG for the details Open collector output Between 11 and CM2 Voltage drop during ON 4V or less Max allowable voltage 27V Max allowable current 50mA CM2 Commonfor intelligent output terminals Common for the terminal 11 Max allowable current 100mA Relay AL0 AL1 AL2 Intelligent relay outputs One fun...

Page 10: ... An inverter run by a private power generator may overheat the generator or suffer from a deformed output voltage waveform of the generator Generally the generator capacity should be five times that of the inverter kVA in a PWM control system or six times greater in a PAM control system In the case of important equipment to shorten the non operational time of inverter failure please provide a back...

Page 11: ...AWG14 2 0 M3 5 7 6 1 0 EX30 10A H10C 10A 0 75 007SB AWG14 2 0 M4 10 1 4 EX30 15A H10C 15A 1 5 015SB AWG10 5 5 M4 10 1 4 EX30 20A H20 20A 2 2 022SB AWG10 5 5 M4 10 1 4 EX30 20A H20 30A 3 phase 200V 0 2 002LB AWG16 1 25 M3 5 7 6 1 0 EX30 5A H10C 10A 0 4 004LB AWG16 1 25 M3 5 7 6 1 0 EX30 10A H10C 10A 0 75 007LB AWG16 1 25 M3 5 7 6 1 0 EX30 10A H10C 15A 1 5 015LB AWG14 2 0 M4 10 1 4 EX30 15A H10C 15A...

Page 12: ...for each operator for the detailed information 3 5 line LCD operator WOP WOP having serial number of 16918938000081 or later 2011 07 production is applied to NE S1 series inverter English only WOP can be used with connector cable ICS 1 3 and connected to the RS422 RS485 port RJ45 in the inverter Turn the changeover switch to the operator side OFF side in that case See page 9 Refer to the manual fo...

Page 13: ...red up with pressing the RUN STOP RESET key and keep it pressing 5seconds and take off from the key Changeover switch must be changed later on Note 1 RS422 RS485 port RJ45 This is a port for external operator Modbus connection or ProDrioveNext RS485 operator changeover switch must be operated before Power ON In case of Modbus communication it is necessary to set the changeover switch and parameter...

Page 14: ...meters as needed Function Name Code Setting Range Note Acceleration time F002 0 00 to 3600 sec default 10 sec Deceleration time F003 0 00 to 3600 sec default 10 sec One of the following is required when changing default parameters on NE S1 series inverters Dedicated operator NES1 OP Digital operator 5 line LCD operator Modbus PC programming tool ProDriveNext 3 Method to perform driving in FW RV te...

Page 15: ...al input signal 3 wire input possible Modbus Option Operator Dedicated Operator Intelligent input terminal 5terminals Analog input 1terminal O OI terminal Voltage input10bit 0 to 10V Current input 10bit 0 to 20mA selected with a selection switch Output signal Intelligent output terminal 5 open collector output terminals 1 relay 1 from c contact output terminal Pulse Output 1terminal connection RS ...

Page 16: ...use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE HITACHI INDUSTRIAL EQUIPMENT SYSTEMS PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM See also product catalogs Model W mm H mm D mm D1...

Reviews: