6 MAINTENANCE
6-15
6.6 Trace
IR.LINK trace is started in the error stop mode (stop of trace at occurrence of an error) when the
CPU unit is reset or the LPU unit is reset and the power supply of each unit is recovered.
The trace data structure is shown below.
+00
Type
+02
Return
code
+04
Free
+06
+08 20-byte data from beginning
of send or receive buffer in
physical layer
+1A
+1C
Timer counter value
(Lapse time from CPU reset)
+1E
Figure 6-4 Trace Data Structure
(1) Type
Table 6-6 Meaning of Each Type in the Trace Data
3010 I/O service transmission error
3030 Initialization service transmission error
4010 I/O service reception error
4030 Initialization service reception error
・
・
・