Temperature. Under 25°C.
Manual Rev. 0.0 - April 2016
1-22
Section 1 - Introduction (UHF Digital TV Transmitters)
E-Compact - Air Cooling - ATSC - High Power
E-Compact Series - Installation CheckList
(Use before turning the transmitter on for the first time)
Task
Description
Electrical. External Grounding from the AC panel.
Cabinet. Physical grounding to the Station grounding.
Hyper-Terminal, ready for monitoring
Ethernet, ready for remote control
Internal Control Connection, back of the Exciter
RS485 connections - rear panel of the RF Power Amplifiers
AC Cable, 220Vac to the exciter rear panel, to the cabinet power outlet.
Ground. Into the cabinet.
Phase 1. Main Breaker, or rear bottom conection poles.
Phase 2. Main Breaker, or rear bottom connection poles.
Phase 3. Main Breaker, or rear bottom connection poles.(Three-phase
transmitters).
Neutral: Rear bottom connection (380 VAC three-phase transmitters)
AC Connectors - Rear panel of RF PAs.
Individual RF Drawer - Cabinet AC Grounding cables. Rear Panel of PAs.
Individual Exciter-Cabinet AC Grounding cable. Rear Panel of Exciter
No-Breaks / voltage stabilizers.
ASI IN.Transport Stream IN. Exciter to the top the cabinet.
RF SAMPLE Before Filter. Exciter to the External Dir. Coupler before the
mask filter.
Exciter RF output to the Splitter. Inside the cabinet.
ASI OUT. Exciter to the top the cabinet..
GPS Antenna. Exciter to the top the cabinet. If applicable.
Tuner Antenna. Exciter to the top the cabinet. If applicable.
High power
RF passives
Connection of rigid line, coaxial cable and curves.
Cleaness. Few or no dusty stress.
Grounding
Low power
cables
Electrical
220Vac power
cable
Coaxial low
power cable
Operating
environment
RF SAMPLE After Filter. Exciter to the External Dir. Coupler after the mask
filter.