![Hitachi EC701HP Operation Manual Download Page 107](http://html.mh-extra.com/html/hitachi/ec701hp/ec701hp_operation-manual_146799107.webp)
5-31
Section 5 - System Operation Manual
(E-Compact ATSC Transmitters - EC701HP thru EC708HP)
Measurements
Menu Indications
Measurements
Sub-Set Indications
Description
Int GPS
This field displays NO SIGNAL or UNKOWN SIGNAL in the
absence of a proper input signal. When validated, shows the PPS
phase and frequency difference between this reference and the
current PPS obtained with the internal control system of the OCXO
(delivered on PPS output connector). When this input is identified
as current reference a message identifies if the OCXO is in the
frequency or phase locking process.
Ext PPS
This field displays NO SIGNAL or UNKOWN SIGNAL in the
absence of a proper input signal. When validated, shows the PPS
phase and frequency difference between this reference and the
current PPS obtained with the internal control system of the OCXO
(delivered on PPS output connector). When this input is configured
as current reference a message identifies if the OCXO is in the
frequency or phase locking process.
Ext 10M
This fi eld displays NO SIGNAL or UNKOWN SIGNAL in the
absence of a proper input signal. When validated, shows the
frequency difference between a PPS generated with this reference
and the current PPS obtained with the internal control system of
the OCXO (delivered on PPS output connector). When this input is
configured as current reference a message identifies if the OCXO
is in the frequency or phase locking process and the phase
difference is also available.
Cur TS
This field displays NO SIGNAL or UNKOWN SIGNAL in the
absence of a proper input signal. When validated, shows the
frequency difference between a PPS generated with this reference
and the current PPS obtained with the internal control system of
the OCXO (delivered on PPS output connector). When this i nput is
configured as current reference a message identifies if the OCXO
is in the frequency or phase locking process and the phase
difference is also available.
Cur Cal
Current value of the frequency control of the OCXO, range
comprehended between 0 (0% , order of magnitude -1500ppb) and
262143 (100%, order of mag1500ppb)
Last Cal
Last calibrated value (zero frequency difference and less then
100ns phase difference) of the frequency control of the OCXO,
range comprehended between 0 (0%, order of magnitude -
1500ppb) and 262143 (100%, order of mag1500ppb)
Clock Measurements
Time Lock
Time counter since achieved lock
15V
Status of power supply of 15V
8V
Status of power supply of 8 V
Eqp. Power Supply
50V
Status of power supply of 50V
Manual Rev. 0.1 - February 2018