3-14
Manual Rev. 0.0 - March 2018
Section 3 - Installation (ATSC EC701HP Transmitter)
3.5.2
Power Drawer
INDICATOR LEDS
USB INTERFACE
ON/OFF SWITCH
Figure 3-9
Front View of Power Drawer - Module MOD GV 40001 / 40087
Changing Functions of the LED’s of the GV 40001 front panel
1) Status dos LEDs
Green light indicates OK
Orange light indicates that ocurred a failure
Flashing Red light indicates that is ocurring a failure
LED’s Functions - MOD GV 40001 HP.PA
TEMP
FAN /
High power drawer input air temperature (greater than 35ºC).
FAN3 Failure, PSU FAN Failure,
LED
ALARM
PWR
This LED lights only GREEN indicating that is POWERED ON.
SHDN
Power Supply Shutdown
FWD
Over Forward Power
RFD
Re?ected Power
PA
PA Failure, High Current on PA, Low Current on PA, Current UNBAL on PA, Low Gain on PA, High Temperature on PA
Com munication Failure on PA.
DRV
High Current on Driver, Low Current on Driver, Low Current on Pre Driver, High Current on Pre Driver, Low Gain on
Driver, High Temperature on Driver, Low Voltage on Driver, Communication Failure on Driver, High Input Signal, High
Driver Output Level.
PSU
Low AC Line Voltage, High AC Line Voltage, Low PSU Voltage, High PSU Voltage, High PSU Current, High PFC
Temperature, High DC/DC Temperature, PSU Communication Failure.
Low Speed on FAN1, Low Speed on FAN2, Low Speed on FAN3, Low Speed on PSU FAN, FAN1 Failure, FAN2
Failure,