![Hitachi DS240 Service Manual Download Page 164](http://html.mh-extra.com/html/hitachi/ds240/ds240_service-manual_145961164.webp)
BMC
Q
UICK
B
UTTON
AND
L
OGGED
-
IN
U
SER
5-23
Note:
Command privilege level table defined in IPMI 2.0 Specification Appendix G –
Command Assignments. According to IPMI 2.0 Specification,
Chassis Identify
command is allowed for Operator privilege. Because this command didn’t change
BMC configuration, just to trigger Identify LED used to display where Server is. So it
is expected behavior. After checked other Operator privilege command by IPMI 2.0
Specification,
Chassis Control command
(Power On/Off ) is also allowed. But in
our code base, we raise
Chassis Control
command to be Administrator to protect
system. So, in
Server Power Control
page, only Administrator can control server
power.
Login BMC through SSH
ID:
sysadmin
, Password:
superuser
Web Account can’t login SSH
SMASH
If supported SMASH then to login SSH will go to SMASH.
If NOT Support SMASH then to login SSH will go to BMC console.