![Hitachi DS240 Service Manual Download Page 156](http://html.mh-extra.com/html/hitachi/ds240/ds240_service-manual_145961156.webp)
BMC
SMASH
5-15
*The sensor name list depends on the Server Hardware.
/system/power
This command provides the specification of the Sensor Type sensor-specific event.
*The sensor name list depends on the Server Hardware.
Table 5.6: /system/temp
P
ROPERTY
N
AME
V
ALID
V
ALUE
A
CCESS
D
ESCRIPTION
Sensor name list of
temperature
na
ok
nonCritical
critical
R
na
indicates the status not available/unknown
(typically because system power is OFF)
ok
indicates the monitored parameters within
normal operating ranges
nonCritical
indicates the hardware outside normal
operating range
critical
indicates the hardware exceeding specified
ratings
Table 5.7: /system/power
P
ROPERTY
N
AME
V
ALID
V
ALUE
A
CCESS
D
ESCRIPTION
Sensor name list of
power supply
Presence*
Power Supply Fail-
ure Detected*
Predictive Fail*
Power Supply
Input Lost(AC/
DC)*
AllDeasserted
(*Note: Only for
certain models.)
R
Presence Detected
indicates the Power Supply Presence detected
Power Supply Failure Detected
indicates the Powser Supply Failure detected
Predictive Fail
indicates the Power Supply Predictive Failure ,
available from Grantley platform
Power Supply Input Lost(AC/DC)
indicates the Power Supply input lost, such as
power cord not inserted
All Deasserted
indicates the power supply is not inserted
Redundancy
Fully Redundant
Redundancy Lost
R
The property is provided depend on project.
Fully Redundant
Indicates the power redundancy is OK.
Redundancy Lost
Indicates the power redundancy is failed. One
PSU is removed or AC lost.
PSUx_FanDir_Err
Asserted
Deasserted
R
Asserted
PSU fan direction is incorrect
Deasserted
PSU fan direction is correct