Put Cloth or Paper
Transport the product as close to the installation location as
practical before unpacking.
·
Handling Method
When hanging the unit, ensure a balance of the unit, check
safety and lift up smoothly.
(1) Do not remove any packing materials.
(2) Hang the unit under packing condition with two ropes,
as shown in Fig below.
·
Handling
If have no package to move, Please protect with cloth
or paper.
CAUTION
:
Before choosing the installation site, obtain user approval.
·
Where it is not exposed to strong wind.
·
Where airflow is good and clean.
·
Where it is not exposed to rain and direct sunshine.
·
Where neighbors are not annoyed by operation sound or hot air.
·
Where rigid wall or support is available to prevent the increase of operation sound or vibration.
·
Where there is no risk of combustible gas leakage.
·
Where it is at least 3m away from the antenna of TV set or radio. An amplifier may be required for the affected
device.
·
Install the unit horizontally.
·
Please install it in an area not affected by snowfall or blowing snow. In areas with heavy snow, please install a
canopy, a pedestal and/or some baffle boards.
Avoid the following places for installation where air conditioner trouble is liable to occur.
·
Where there is much machine oil.
·
Salty places such as seaside.
·
Where sulfide gas is generated such as a hot spring.
·
Where there is high-frequency or wireless equipment.
NOTE:
When operating the air conditioner in low outside temperature, be sure to follow the instruction describe below.
·
Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.
·
To prevent exposure to wind, install the outdoor unit with its air inlet side facing the wall.
·
To prevent exposure to wind, it is recommended to install a baffle board on the air outlet side of the outdoor unit.
Transportation and handling before
installation
Installation locations selection
Drainage elbow and drain hose installation
Installation instructions
Install Drainage Elbow and Drain Hose
·
The condensate water may drains from the outdoor unit
when the unit operates in heating mode. In order to avoid
disturbing neighbors also to protect the environment, it is
necessary to install a drainage elbow and a drain hose to
drain out the condensate water.
·
Please do the drainage work before the indoor unit and
outdoor unit are connected. Otherwise, it will be difficult
to install drainage elbow after the machine becomes
immovable.)
·
Connect the drain hose (
field-supplied
, inside diameter:
15mm) as shown in the figure for drainage.
Drain hose
Drainage elbow
NOTE
:
Do not use the drain elbow in the cold region. Drain
may freeze to stop the fan runs.