Safety precautions
WARNING
• Appliance shall be installed, operated and stored in a room with a floor area larger than X (X see indoor unit
instruction manual).
• The installation of pipe-work shall be kept to a a room with a floor area larger than X (X see indoor unit
instruction manual).
• The pipe-work shall be complianced with national gas regulations.
• The maximum refrigerant charge amount is X kg (X see below).
• When moving or relocating the air conditioner, consult experienced service technicians for disconnection and
reinstallation of the unit.
• Do not place any other electrical products or household belongings under indoor unit or outdoor unit.
• Condensation dripping from the unit might get them wet, and may cause damage or malfunction of your property.
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer
.
• The appliance shall be stored in a room without continuously operating ignition sources
(
for
example
:
open flames, an operating gas appliance or an operating electric heater)
.
• Do not pierce or burn
.
• Be aware that refrigerants may not contain an odour
.
• To keep ventilation openings clear of obstruction.
• The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as
specified for operation.
• The appliance shall be stored in a room without continuously operating open flames (for example an operating
gas appliance) and ignition sources (for example an operating electric heater).
• Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment specification.
• Servicing shall only be performed as recommended by the equipment manufacturer.
• Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the
supervision of the person competent in the use of flammable refrigerants.
• The appliance shall be installed and stored so as to prevent mechanical damage from occurring.
• Mechanical connectors used indoors shall comply with ISO 14903. When mechanical connectors are reused
indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be
re-fabricated.
• The installation of pipe-work shall be kept to a minimum.
• Mechanical connections shall be accessible for maintenance purposes.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this appliance uses a flammable
refrigerant.
If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire.
CAUTION
This symbol shows that the operation manual should be read
carefully.
CAUTION
This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
CAUTION
This symbol shows that information is available such as the
operating manual or installation manual.
Safety precautions
8
Series
Up to 2 indoor units
Up to 3 indoor units
Model
35/42
52
62
72
Max. Refrigerant
charge (kg)
1.19
1.29
1.87
1.87
Max. Refrigerant Charge Amount X(kg)