Operator’s / Service Manual, PRS 40 EZ
© PRS 40 EZ REV A 03/16/06
190201_A
4
Since button C can deactivate the lockout function of the system, the following instructions
must be obeyed:
•
The by-pass function shall be used with discretion, as unwarranted use of it to override
the control lever lockout system can result in harm to the crane and danger to property
and persons.
•
Never use the by-pass function to either overload or operate the crane in a non-
permissible range.
4.2 OPERATION
Upon switching on crane ignition switch, the system starts with an automatic test of the system, of
lamps and audible alarm. During the test, the LCD shows the console and system software version.
The PRS 40 EZ setup procedure allows the operator to input the sensors being used and the limits for
the sensors. The operator must complete the setup procedure for each sensor.