Angle
© PRS 40 EZ REV A 03/16/06
190201_A
9
Hardwired (Kruger)
Note for older system updates, use the hardwired option. For example if replacing a Krueger AP
console and using the existing sensor, select the
hardwired
option.
Set the internal DIP switch to:
Voltage Angle sensor -
SETUP 3
Select the "HARDWIRED" from the following menu.
MENU/ SENSORS/ ANGLE/ HARDWIRED/ KRUEGER
5.1.4 Calibration
Both the radio and the hardwired sensors are calibrated with the same procedure. The angle sensor
is pre-calibrated at the factory, but it still must be matched to the boom angle. A level, accurate to +/-
.2 degrees must be used to set the boom to a known angle.
Go to the menu for calibration of the angle:
MENU/ SETUP/ CALIBRATION/ ANGLE
1. Once the boom angle is determined and the sensor is securely mounted, enter the angle setting
screen. This screen is used to match the angle sensor to the angle of the boom.
2. Scroll to the correct angle and press OK.