8.1.4 Loadcell Setup
In order to use the loadcell, the loadcell must first be installed into the system. Add the loadcell to the
console by pressing
HARDWIRED
SETUP / SENSORS / INSTALL-REMOVE / LOADCELL / HARDWIRED.
RADIO
Add the radio loadcell to the console by pressing
SETUP / SENSORS / INSTALL-REMOVE / LOADCELL / RADIO.
The console will show "SEARCHING". Remove the batteries from the transmitter. Reinstall the
batteries into the transmitter. The LED on the transmitter will be on for 3 seconds and then start to
flash on and off. The sensor should now be set up.
When the transmitter is powered up (after batteries removed and replaced) the transmitter LED will be
on for 3 seconds to indicate the transmitter is setup for a loadcell.
Press
when complete.
8.1.4.A LOADCELL
RANGE
Use the following menu selection as an example to select the correct load cell. The following is an
example for setting the 7.5 ton load cell.
SETUP / CALIBRATIONS / LOAD RANGE / LOADCELL TYPE / 7.5 TON.
8.1.5 Loadcell Calibration
ZERO POINT SETTING
The load cell being zeroed must be installed and communicating with the console and there should be
no load applied to the load cell. Use the following menu selection to set the zero point of the load cell.
SETUP / CALIBRATIONS / LOAD 0-POINT
Press