Working voltage
with the
characteristic
value W
Power supply through a 7/8" connector or PoE
Nominal voltage DC
24 V
Class 2
Voltage range DC incl.
maximum tolerances
18 V ... 32 V
Connection type
4-pin, 7/8" connector
Power failure bypass
> 10 ms at 20.4 V DC
Overload current protection at
input
Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
Max. 6.3 A
slow blow
Climatic
conditions
during operation
Ambient air temperature
a
.
Devices with operating temperature
characteristic value S (standard):
0 °C ... +60 °C (+32 °F ... +140 °F)
Devices with operating temperature
characteristic value E and T (extended):
−
40 °F ... +158 °F (
−
40 °C ... +70 °C)
b
Humidity
10% ... 95%
Air pressure
Up to 2000 m (795 hPa), higher altitudes on
request
maximum 1060 hPa (
≈
−
1312 ft (
−
400 m))
Climatic
conditions
during storage
Ambient air temperature
c
.
−
40 °F ... +185 °F (
−
40 °C ... +85 °C)
Humidity
10% ... 95%
Air pressure
minimum 700 hPa (
≈
+9842 ft (+3000 m))
maximum 1060 hPa (
≈
−
1312 ft (
−
400 m))
“FAULT”
signal contact
Switching current
max. 1 A, SELV
Switching voltage
Power supply unit characteristic value C
and K:
max. 60 V DC or max. 30 V AC, SELV
Working voltage with the characteristic
value W:
max. 30 V DC, SELV
Pollution degree
2
Protection
classes
Laser protection
Class 1 in compliance with IEC 60825-1
Degree of protection
IP65/67
a. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
b. Only use SFP transceivers with the “EEC” extension.
c. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device