Installation BAT-F
Release 06 02/2014
Connect the wires for the working voltage according to the pin assignment
with a suitable socket.
2.6.2
Working voltage with the characteristic value K
For
every
working voltage to be connected, perform the following steps:
Connect the wires for the working voltage and the protective ground
according to the pin assignment with a suitable socket.
Type of the
voltages that can
be connected
Specification of the working
voltage
Pin assignment on the device
DC voltage
Rated voltage range DC
60 V ... 250 V
1 Protective conductor
Voltage range DC incl.
maximum tolerances
48 V ... 320 V
2 Plus terminal of the
working voltage
3 Minus terminal of the
working voltage
AC voltage
Rated voltage range AC
110 V ... 230 V, 50 Hz ...
60 Hz
1 Protective conductor
Voltage range AC incl.
maximum tolerances
88 V ... 265 V, 47 Hz ... 63 Hz
2 Outer conductor
3 Neutral conductor
Table 15: Working voltage with the characteristic value K: Type and specification of
the working voltage, pin assignment on the device
WARNING
ELECTRIC SHOCK
Start connecting the electrical wires solely if
all
the above requirements are
fulfilled.
See “Working voltage” on page 6.
Install this device solely in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.