Installation BAT-F
Release 06 02/2014
31
1.9
Management interfaces
1.9.1
V.24 interface (external management)
This interface is designed as an 8-pin, A-coded M12 plug.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
You will find more information here:
–
See table 10 on page 32.
BAT-F device. Connecting the BAT-F device allows you to automate the
configuration of a point-to-point WLAN line by connecting two devices
directly via the serial interface.
You will find more information here:
– User Manual Configuration and Administration Guide
–
See table 11 on page 32.
The socket housing is electrically connected to the housing of the device. The
V.24 interface is electrically insulated from the working voltage.
Note:
Only use a shielded cable.
VT 100 terminal settings
Speed
115200 bit/s
Data
8 bit
Stopbit
1 bit
Handshake
Hardware
Parity
none
Pins of the M12 socket
on the device
Pin
Function
Description of functions
1
GND
Ground
2
DTR
Data terminal ready
3
TxD
Transmit data
4
RxD
Receive data
5
DCD
Data carrier detect
6
DSR
Dataset ready
7
RTS
Request to send
8
CTS
Clear to send
Table 9:
Pin assignment of the V.24 interface, 8-pin, A-coded M12 socket
8
2
3
4
7
6
1
5
Summary of Contents for BAT-F