1. TM-1 Timing chart
(used for the tightening of screws before final tightening)
1) Turn the power ON.
2) Set the work piece and enter the SET signal.
•
If the SET signal changes from ON to OFF while the Work Set Timer is active, the unit
is designed to be fully operational even with the Work Set Timer remaining in the off
position.
3) Start of Work Set Timer.
4) Work Set changed, make fixes.
5) End of Work Set Timer.
6) The red DRV LED on the front panel will light, and the electric screwdriver will become
usable.
7) Start of VALVE signal output.
8) Manually turn ON electric screwdriver with start lever.
9) Start of electric screwdriver operations.
10) Start of Count Timer operations.
11) End of Count Timer operations.
12) Complete tightening of screws, perform torque-up procedure.
13) End of electric screwdriver operations.
14) Count-down from set number of screws. Number of Screws LED decreases by one.
15) Manually turn OFF electric screwdriver with start lever.
16) Manually turn ON electric screwdriver with start lever to perform confirmation tighten-
ing.
17) Start of electric screwdriver operations.
18) Start of Count Timer operations.
19) Immediate torque-up operations to perform confirmation tightening.
20) Count Timer is reset during operation for the torque-up procedure.
21) Count-down will not proceed due to torque-up procedures while the Count Timer is
operational.
22) End of electric screwdriver operations.
23)Manually turn OFF electric screwdriver with start lever.
2. TM-2 Timing chart
(used for tightening of screws)
1) Select reverse rotation using the FOR/REV SW.
2) Manually turn ON electric screwdriver with start lever.
3) Start of electric screwdriver reverse operations.