![HIOS BLOP-STC 3 Operation Manual Download Page 18](http://html1.mh-extra.com/html/hios/blop-stc-3/blop-stc-3_operation-manual_2137591018.webp)
■
Quick installation
1. Normal power mode
✽
When performing tightening of screws using the equipment as a normal power supply for
an electric screwdriver without using the external device control or counter function.
■
Connections
1) Connect the connector for the screwdriver cord to the metal connector of this equip-
ment.
2) Connect the power supply cord for this device to a power supply that supplies the rated
power (AC outlet), and connect to ground.
■
Setup and work instructions
1) Set 80 in the System Setting Mode (F1 Display " ").
2) Exit the Setting Mode by pressing the F1 switch for longer than 1 second.
3) After work preparations are complete, tighten screws as normal.
2. Continuous counter mode
✽
When the external device control function of this equipment is not used and only the
counting function is used for performing work.
This mode is for cases where work pieces are not fixed and for use of a target count to
prevent careless mistakes.
■
Connections
1) Connect the connector for the screwdriver cord to the metal connector of this equip-
ment.
2) Connect the power supply cord for this device to a power supply that supplies the rated
power (AC outlet), and connect to ground.
■
Setup instructions
1) Set F3 "2" (Do not use torque-up buzzer) in System Setting Mode (F1 Display " "), or
F3 "3" (Use torque-up buzzer).
Set F2 "0
-
7" depending on conditions of use.
2) Set the number of screws to be tightened using the Count Setting Mode (F1 Display " ").
3) Set the Counter Timer operating time using the CN-T Setting Mode (F1 Display " ")
switch (range of 0.01 second to 0.99 second) while performing confirmation tightening.
4) Exit the Setting Mode by pressing the F1 switch for longer than 1 second.
5) Preparation settings are now complete.
- 17 -
Summary of Contents for BLOP-STC 3
Page 14: ...Function Setting Table 13...