3) WS-T (Work Set Timer) Setting Mode (Display " ")
•
Setting range from 0.1 second to 3.9 seconds.
•
This setting changes the time allotted until the screwdriver is operational, as well as
generating a valve signal when the set signal is received by the terminal block.
•
Use the time taken for the LED to light after receiving the set signal as a guide to set-
ting the Work Set Timer.
4) WR-T VR (Work Set Timer) Setting Mode (Display " ")
•
Setting range from 0.1 second to 3.9 seconds.
•
Set the time between the end of the valve signal after work has been completed, and
the time for which the screwdriver is not operational.
•
Use the time taken between the start and end of the buzzer sound after work has been
completed, as a guide to setting the Work Reset Timer.
5) REV-T (Reverse Timer) Setting Mode (Display " ")
for BLOP-STC 3
•
Setting range from 0.1 second to 1.0 second.
•
Set the time taken until reverse counting starts.
•
Use the time taken to the start reverse counting as a guide to setting the Work Reset
Timer.
6) System Setting Mode (Display " ")
•
Settings for the following features are available.
a) Controls display of remaining number of screws, see page 12 : ON=display,
OFF=no display
b) Controls buzzer sound: ON=buzzer noise, OFF=no buzzer noise
c) Controls reverse count: ON=on, OFF=off
d) Controls the normal counter operating mode with a signal on set terminal, see page
10 : ON=on, OFF=off
e) Controls buzzer sound during torque-up: ON=on, OFF=off
f ) Stops all counting features: power supply only
Note: REV-T(Reverse Timer) is valid only for BL-OPC and BLG-OPC type screwdrivers.
* Reverse Timer is to define the time wether count-up or not while reversing the screwdriver.
* The counter count-up when the screwdriver is reversed longer than this timer.
<Caution>
•
Note: Even the slightest reverse rotation will be considered as loosening and result in a
count-up from the last screw of the operation with a count of 00, regardless of the time
set for the reverse count timer.
•
The reverse count feature cancels the countdown of the preceding torque-up operation.
Once reverse count-up has started, further count-up will not occur until count-down
from a normal rotation torque-up operation has occurred.
- 9 -