![HIOS BLOP-STC 3 Operation Manual Download Page 13](http://html1.mh-extra.com/html/hios/blop-stc-3/blop-stc-3_operation-manual_2137591013.webp)
•
However, operation of this device can be actuated normally by the number of screws
remaining to be tightened for completion.
•
ER BZ output does not stop until there is a reset or count-down is completed.
•
When a separate power supply is used for the external device, connect the devices to a
common ground and use an external power supply.
•
Add a diode to the solenoid valve of external devices to absorb reverse voltage.
•
The output type is open collector output, and the maximum rated load is 30V DC/80
mA.