![HIOS BLOP-STC 3 Operation Manual Download Page 22](http://html1.mh-extra.com/html/hios/blop-stc-3/blop-stc-3_operation-manual_2137591022.webp)
■
Setup and work instructions
1) Set A using the following procedures.
•
Set 20 in the System Setting Mode (F1 Display " ").
•
Set the number of screws to be tightened using the Count Setting Mode (F1 Display
" ").
•
Set the Work Set Timer operating time to suit the work piece using the WS-T Setting
Mode (F1 Display " ") switch (range from 0 second to 3.9 seconds).
•
Set the Counter Timer operating time using the CN-T Setting Mode (F1 Display " ")
switch (range of 0.01 second to 0.99 second) while performing confirmation tightening.
•
Set the Work Reset Timer operating time to 0.0 using the WR-T Setting Mode (F1
Display “ ”).
•
Exit the Setting Mode by pressing the F1 switch for longer than 1 second.
2) Set B using the following procedures.
•
Set 00 in the System Setting Mode (F1 Display " ").
•
Set the number of screws to be tightened using the Count Setting Mode (F1 Display
" ").
•
Set the Work Set Timer operating time to suit the work piece using the WS-T Setting
Mode (F1 Display " ") switch (range from 0 second to 3.9 seconds).
•
Set the Counter Timer operating time using the CN-T Setting Mode (F1 Display " ")
switch (range of 0.01 second to 0.99 second) while performing confirmation tightening.
•
Set the Work Reset Timer operating time to suit the work piece using the WR-T Setting
Mode (F1 Display " ") switch (range from 0 second to 3.9 seconds).
•
Exit the Setting Mode by pressing the F1 switch for longer than 1 second.
3) Preparation settings are now complete.