85
Output File Formats
7.3 Output File Formats
Analysis results file format
Header
Description
Counter
Counter [measurements]
Date
Measurement start date
Time
Measurement start time
Comment
Comment (up to 30 characters)
Composite volume resistivity [ohm cm]
Composite layer volume resistivity [
Ω
cm]
Interface resistance [ohm cm^2]
Interface resistance [
Ω
cm
2
]
Composite surface resistivity [ohm cm^2]
Composite layer surface resistivity [
Ω
cm
2
]
Range [ohm]
Resistance range
Speed
Potential measurement speed
TF-Type
Fixed value of 1
Composite layer thickness [um]
Composite layer thickness [μm]
Collector layer thickness [um]
Collector thickness [μm]
Collector resistivity [ohm cm]
Collector volume resistivity [
Ω
cm]
Model area
Model area {NORMAL | MEDIUM | WIDE}
Element size
Element size {NORMAL | FINE | SUPER FINE}
Limit iteration number
Limit iteration number [iterations]
Reduction factor
Reduction factor
Initial composite resistivity [ohm cm]
Composite layer volume resistivity initial value setting [
Ω
cm]
Initial Interface resistance [ohm cm^2]
Interface resistance initial value setting [
Ω
cm
2
]
Contact check-V
Contact check results (32-bit hexadecimal value) (p. 87)
Contact check-I
Contact check results (32-bit hexadecimal value) (p. 87)
Potential consistency
Potential distribution consistency
Variation-V
Potential variability [%]
Error data
Number of error data rejections [rejections]
Measurement Time [s]
Potential measurement time [s]
Temperature [deg C]
Temperature [°C]
Calculation
Analysis results {PASS | FAIL}
Iteration number
Iteration number [iterations]
Coincidence
Coincidence
Calculation Time [s]
Analysis time [s]
RM2611 SN
RM2611 Electrode Resistance Meter serial number
RM2611 Version
RM2611 Electrode Resistance Meter firmware version
RM2612 Version
PC application version
RM2612 Analysis version
Analysis unit version
10
9
8
7
6
5
4
3
2
1
索引
7
Specifications
Summary of Contents for RM2610
Page 2: ......
Page 12: ...8 Operating Precautions...
Page 22: ...18 USB License Key and Screens RM2612 Resistance Calculation Software...
Page 54: ...50 Checking Measurement Results...
Page 72: ...68 Setting Administrator Mode...
Page 110: ...106 Under what circumstances do contact errors occur...
Page 128: ...124 Dimensional Drawings 10 2 Dimensional Drawings RM2611 Electrode Resistance Meter Unit mm...
Page 130: ...126 Dimensional Drawings RM9005 Connection Cable Unit mm...
Page 134: ...130 Index...
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......