5.4 Creating Condition Settings Files
43
* A system of numerical notation based on the number 16. The 10 digits represent the numbers 0
through 9, while the letters A, B, C, D, E, and F are used for the decimal numbers 10, 11, 12, 13,
14, and 15.
3
Click
[OK]
to accept the settings.
The dialog box will close.
(You can click
[Cancel]
to close the dialog box without adding the definition.)
Setting Contents (
Default setting)
ActMode
One Shot
: Sends one message only.
Response
: Sends responses to the ID set with
[RespID]
. Re-
sponses are sent as soon as the set ID is received, and
no delay time before frame transmission can be set.
Interval*
: Sends messages regularly at the interval set with
[In-
terval]
.
One Shot Program : Sends messages tagged for
[One Shot Program]
one
at a time, starting with the lowest number and proceed-
ing in order until each has been sent once. The interval
between the transmission of one program and the next
is set with
[Interval]
.
Repeat Program
: Repeatedly sends messages tagged for
[Repeat Pro-
gram]
in order, starting with the lowest number. The in-
terval between the transmission of one program and
the next is set with
[Interval]
.
Port1 / Port2
Selects the CAN port with which to send the frame.
FrmType
Data frame*
: Sends a data frame.
Remote frame: Sends a remote frame.
SendID
Sets the frame ID to use to send the set content as a hexadecimal value.
(Valid setting range: 1 to 1FFFFFFF)
Len
Enter the byte length of the frame to send. (Valid setting range: 0 to 8)
SendText
Enter the text to send with the
[SendID]
frame as a hexadecimal value.
Input boxes for the length specified with
[Len]
will be displayed, and one
byte of data should be entered into each.
(For example, if
[Len]
is 4, 01 45 AB EF.)
RespID
The set frame will be sent when a port with the message ID (hexadecimal*)
set here is received.
This setting is valid when
[ActMode]
is set to
[Response]
.
(Valid setting range: 1 to 1FFFFFFF)
Interval
Sets the interval at which to send the frame ID set here as a multiple of 10
ms. This setting is valid only when
[ActMode]
is
[Interval]
,
[One Shot Pro-
gram]
, or
[Repeat Program]
.
(Valid setting range: 1 to 9,999 [X 10 ms])
Since it is not possible to send and receive data simultaneously, when allocating a definition
with the same ID as the transmit frame to be received by the same port as used for trans-
mission, the set transmit frame will not affect measured values.
Summary of Contents for MR8904
Page 1: ...MR8904 Instruction Manual CAN UNIT EN Sept 2018 Revised edition 3 MR8904A981 03 18 09H...
Page 2: ......
Page 10: ...Usage Notes 6...
Page 14: ...10...
Page 24: ...3 3 Connecting the Unit to a PC 20...
Page 66: ...7 4 MR8904 CAN Editor General Specifications 62...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......