76
Accuracy table
(5)
AC voltage
Measured value, maximum value, minimum value, average
Range
(automatic
ranging
threshold)
Accuracy
guarantee
range
(resolution)
Accuracy
guarantee
frequency range*
1
*
2
Measurement accuracy
Input
impedance*
3
Filter disabled Filter enabled
6.000 V (more
than 6000
counts)
0.000 V to
0.299 V
(0.001 V)
15 Hz ≤ f< 45 Hz
±1.5% rdg
±0.015 V
±2.0% rdg
±0.015 V
3.2 M
Ω
±5%
45 Hz ≤ f ≤ 66 Hz
±0.9% rdg
±0.013 V
±1.4% rdg
±0.013 V
66 Hz < f < 1 kHz
±1.5% rdg
±0.015 V
−
0.300 V to
6.000 V
(0.001 V)
15 Hz ≤ f< 45 Hz
±1.5% rdg
±0.005 V
±2.0% rdg
±0.005 V
3.2 M
Ω
±5%
45 Hz ≤ f ≤ 66 Hz
±0.9% rdg
±0.003 V
±1.4% rdg
±0.003 V
66 Hz < f < 1 kHz
±1.5% rdg
±0.005 V
−
60.00 V
(more than
6000 counts,
less than 540
counts)
3.00 V to
60.00 V
(0.01 V)
15 Hz ≤ f< 45 Hz
±1.5% rdg
±0.05 V
±2.0% rdg
±0.05 V
3.1 M
Ω
±5%
45 Hz ≤ f ≤ 66 Hz
±0.9% rdg
±0.03 V
±1.4% rdg
±0.03 V
66 Hz < f < 1 kHz
±1.5% rdg
±0.05 V
−
HIOKI CM4141C961-00
Summary of Contents for CM4141-50
Page 2: ...HIOKI CM4141C961 00 ...
Page 6: ...iv Contents HIOKI CM4141C961 00 ...
Page 24: ...18 Operating Precautions HIOKI CM4141C961 00 ...
Page 94: ...88 Accuracy table HIOKI CM4141C961 00 ...
Page 100: ...94 Cleaning HIOKI CM4141C961 00 ...
Page 104: ...Index 98 HIOKI CM4141C961 00 ...
Page 105: ...HIOKI CM4141C961 00 ...
Page 106: ...HIOKI CM4141C961 00 ...
Page 107: ...HIOKI CM4141C961 00 ...
Page 108: ...www hioki com HIOKI CM4141C961 00 ...