81
Input, Output, and Measurement Specifications
Output specifications
CM4003
Output item
RMS (RMS value output)
WAVE (waveform output)
Output level
RMS: 600 mV DC/f.s. (other than 200.0 A range)
200 mV DC/f.s. (200.0 A range)
(outputs a voltage of 1 V when the f.s. of the range is exceeded.)
WAVE: 600 mV AC/f.s. (other than 200.0 A range)
200 mV AC/f.s. (200.0 A range)
Output accuracy
RMS: ±1.0% rdg ±5 mV (for the display count)
WAVE: ±3.0% rdg ±10 mV (45 Hz to 400 Hz)
±5.0% rdg ±10 mV (15 Hz to 45 Hz, 400 Hz to 2 kHz)
Output response
RMS: Refresh rate: 5 times/s
WAVE: Frequency band: 15 Hz to 15 kHz (Within ±3 dB)
Output impedance
100
Ω
or less
HIOKI CM4002A961-02