© Hills Industries 2006
Page 30
Data
Default Zone Configuration
4
Entry / Exit Delay 2: Partial – Forced Arming
–
A trip will start entry delay 2. This zone will be
active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the
area options.
5
Entry / Exit Delay 2: Partial – Chime – Forced Arming
- A trip will start entry delay 2. This zone
will be active in partial mode. This zone type may be faulted while arming if forced arming is enabled
in the area options. This zone type will set the code pad chime if set via the code pad
[Chime]
key.
6
Handover: Forced Arming
–
Interior zone that follows the entry delay zones. Instant alarm type
unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone type may
be faulted while arming if forced arming is enabled in the area options.
7
Handover: Partial – Forced Arming
– Interior zone that follows the entry delay zones. Instant alarm
type unless an entry zone if faulted first. This zone will be active in partial mode. This zone type may
be faulted while arming if forced arming is enabled in the area options.
8
Handover: Twin Trip – Forced Arming
– Interior zone that follows the entry delay zones. Instant
alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone
type may be faulted while arming if forced arming is enabled in the area options. This zone type will
require two triggers or another zone would have to have been trigged before it will activate an alarm.
9
Handover: Group Isolate – Forced Arming
– Interior zone that follows the entry delay zones.
Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode.
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone
type will be part of the group bypass zones.
10
Handover: Twin Trip – Chime – Forced Arming
– Interior zone that follows the entry delay zones.
Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode.
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone
type will require two triggers or another zone would have to have been trigged before it will activate
an alarm. This zone type will set the code pad chime if set via the code pad
[Chime]
key.
11
Handover: Partial – Twin Trip – Forced Arming
– Interior zone that follows the entry delay zones.
Instant alarm type unless an entry zone if faulted first. This zone will be active in partial mode. This
zone type may be faulted while arming if forced arming is enabled in the area options. This zone type
will require two triggers or another zone would have to have been trigged before it will activate an
alarm.
12
Handover: Partial – Group Bypass – Forced Arming
– Interior zone that follows entry delay
zones. Instant alarm type unless an entry zone if faulted first. This zone will be active in partial mode.
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone
type will be part of the group bypass zones.
13
Handover: Twin Trip – Group Bypass – Forced Arming
– Interior zone that follows the entry delay
zones. Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial
mode. This zone type may be faulted while arming if forced arming is enabled in the area options.
This zone type will require two triggers or another zone would have to have been trigged before it will
activate an alarm. This zone type will be part of the group bypass zones.
14
Handover: Partial – Twin Trip – Group Isolate – Forced Arming
– Interior zone that follows the
entry delay zones. Instant alarm type unless an entry zone if faulted first. This zone will be active in
partial mode. This zone type may be faulted while arming if forced arming is enabled in the area
options. This zone type will require two triggers or another zone would have to have been trigged
before it will activate an alarm. This zone type will be part of the group bypass zones.
15
Instant:
– Produces an instant alarm if tripped when armed. Ignored when disarmed. This zone will
be bypassed in partial mode.
16
Instant: Partial
– Produces an instant alarm if tripped when armed. Ignored when disarmed. This
zone will be active in partial mode.
17
Instant: Partial (no DEOL)
– Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be active in partial mode. This zone type will not be enabled for dual end of
line monitoring if enabled in the system options.
18
Instant: Twin Trip – Forced Arming
– Produces an instant alarm if tripped when armed. Ignored
when disarmed. This zone will be bypassed in partial mode. This zone type may be faulted while
arming if forced arming is enabled in the area options. This zone type will require two triggers or
another zone would have to have been trigged before it will activate an alarm.
19
Instant: Group Bypass
– Produces an instant alarm if tripped when armed. Ignored when disarmed.
This zone will be bypassed in partial mode. This zone type will be part of the group bypass zones.
20
Instant: Partial – Chime
– Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be active in partial mode. This zone type will set the code pad chime if set
via the code pad
[Chime]
key.