© Hills Industries 2006
Page 39
Note:
When event 48 is programmed, it is possible to program a user code's authorization to select which output(s) a
particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 4 correspond to that code activating
outputs 1 - 4 respectively. Refer to the code pad programming section in this manual.
Feature 32
Auto-Test Control
Segments 1-4
1
168
03
00
Segment 1
Program a ’0’ if the intervals are in hours. ‘1 - 8’ if in days.
1 = SUN, 2=MON, 3=TUE, 4=WED, 5=THU, 6=FRI, 7 = SAT and 8 = DAILY
Segment 2
Program the Auto-test
hourly interval
from 1-255 hours, if Segment 1 is set to 0
Segment 3
Program the Auto-test report
hour
in 24 hour format, ignored if Segment 1 is set to 0
Segment 4
Program the Auto-test report time, number of
minutes
after the hour
Feature 33
new
Opening Time / Auto Disarm Time
Segments 1-2
Hours – 08
Minutes – 00
Feature 33 determines the start of the Open Window (in 24 hour format). This is the time when the panel would normally be
disarmed. If Auto Disarm is programmed then this is the time the panel will disarm the selected areas on those days
programmed in Feature 35.
At this time it also enables codes with ‘Arm Only After Close Window’ authority to arm and disarm the panel.
Note: Opening time must be earlier than closing time for Aux. outputs, or Code Authorization to function properly.
Feature 34
Closing Time / Auto Arm Time
Segments 1-2
Hours – 20
Minutes – 00
Feature 34 determines the end of the Open Window (in 24 hour format) and the start of the Close Window. This is the time
when the panel would normally be armed. If Auto Arm is programmed then this is the time the panel will arm the selected
areas. At this time, the Code Pad will beep for 50s before the panel arms. Stop/Delay the auto-arm for 45 minutes by
entering a valid code on the Code Pad. See Feature 36.
At this time it also prevents codes with ‘Arm Only After Close Window’ authority from disarming the panel.
Note: Closing time must be later than opening time for Aux. outputs, or Code Authorization to function properly.
Feature 35
Days Open / ‘Arm Only After Close Window’ Authority
Feature 35 selects which days of the week each area is open. Segment 1 is for area 1, and Segment 8 is for area 8.
Together with F33 and F34, this determines the normal operating hours of the site also known as the Open Window, when
each area would normally be disarmed. The period outside of this time and selected days is known as the Close Window
when each area would normally be armed. If a day is not selected then that entire day will be in the Close Window. If Auto
Arm is programmed, the panel will attempt to arm specified areas during the Close Window. Also see F33, 34 and 36.
Also on these selected days, user codes with ‘Arm Only After Close Window’ authority will be able to arm and disarm during
the Close Window. On days
not
selected here, codes with ‘Arm Only After Close Window’ authority will not disarm. Note
that Feature 36 can re-arm an area even after a user disarms that area if it is during the Close Window.
Segments 1-8
Areas 1 – 8
(1)
‘Arm only after close window’ will arm/disarm on Sunday, and Area is open on Sunday
(2)
‘Arm only after close window’ will arm/disarm on Monday, and Area is open on Monday
(3)
‘Arm only after close window’ will arm/disarm on Tuesday, and Area is open on Tuesday
(4)
‘Arm only after close window’ will arm/disarm on Wednesday, and Area is open on Wednesday
(5)
‘Arm only after close window’ will arm/disarm on Thursday, and Area is open on Thursday
(6)
‘Arm only after close window’ will arm/disarm on Friday, and Area is open on Friday
(7)
‘Arm only after close window’ will arm/disarm on Saturday, and Area is open on Saturday
(8)
Reserved