![HIKVISION DE3W User Manual Download Page 122](http://html1.mh-extra.com/html/hikvision/de3w/de3w_user-manual_2133321122.webp)
User Manual of Network Mini PTZ Camera
© Hikvision
121
Appendix 4 12VDC Wire Gauge & Transmission Distance
The following table describes the recommended max. distance adopted for the certain wire gauge
when the loss rate of 12VDC voltage is less than 15%. For the DC driven device, the maximum
voltage loss rate is 15% allowable.
0.800(20)
1.000(18)
1.250 (16)
2.000(12)
10
97(28)
153(44)
234(67)
617(176)
20
49(14)
77(22)
117(33)
308(88)
24
41(12)
64(18)
98(28)
257(73)
30
32(9)
51(15)
78(22)
206(59)
40
24(7)
38(11)
59(17)
154(44)
48
20(6)
32(9)
49(14)
128(37)
50
19(6)
31(9)
47(13)
123(35)
60
16(5)
26(7)
39(11)
103(29)
70
14(4)
22(6)
33(10)
88(25)
80
12(3)
19(5)
29(8)
77(22)
90
10.8(3.1)
17(5)
26(7)
69(20)
100
9.7(2.8)
15(4)
23(7)
62(18)
110
8.9(2.5)
14(4)
21(6)
56(16)
120
8.1(2.3)
13(4)
20(6)
51(15)
130
7.5(2.1)
11.8(3.4)
18(5)
47(14)
140
7(2)
11(3.1)
17(5)
44(13)
150
6.5(1.9)
10.2(2.9)
16(4)
41(12)
160
6.1(1.7)
9.6(2.7)
15(4)
39(11)
170
5.7(1.6)
9(2.6)
14(4)
36(10)
180
5.4(1.5)
8.5(2.4)
13(4)
34(10)
Appendix 5 Table of Wire Gauge Standards
Bare Wire
Gauge(mm)
American
Wire Gauge
AWG
British Wire
Gauge SWG
Cross-sectional
Area of Bare
Wire(mm
2
)
0.750
21
0.4417
0.800
20
21
0.5027
0.900
19
20
0.6362
1.000
18
19
0.7854
1.250
16
18
1.2266
1.500
15
17
1.7663
2.000
12
14
3.1420
2.500
4.9080
3.000
7.0683
Distance
(feet)
Wire Gauge
(mm)
Power