CameraLink Line Scan Camera
·
User Manual
72
Parameter
Command
Value
Description
r PostDivider
Read PostDivider.
LineMode
w Lx y
x:
5—CC1
0—Line0
1—Line1
3—Line3
4—Line4
y:
0—In
8—Strobe
Set I/O input and output
mode. Eg: w L5 0
(Set CC1 as input).
r Lx
Read I/O input and output
mode.
LineInverter
w LineInverter
0—disable all
2—enable Line1 only
8—enable Line4 only
Enable Line1 or Line4.
Eg: w LineInverter 2 (enable
Line1’s inverter).
r LineInverter
Read LineInverter status.
LineStrobe
w LineStrobe
0—disable all
2—enable Line1 only
8—enable Line4 only
Enable Line1 or Line4.
Eg: w LineInverter 2 (enable
Line1’s inverter).
r LineStrobe
Read LineStrobe status.
LineDebouncerTim
e
w
LineDebounx
y
x:
5—CC1
0—Line0
3—Line3
y: value
Set trigger debouncer, input
is available. Eg: w
LineDeboun5 100.
r
LineDebounx
Read trigger debouncer.
DeviceTapGeomet
ry
w DeviceTapGeometry
x
x:
0x02010181:Geometr
y_2X
0x04010181:Geometr
Set the camera’s
transmission mode. Eg: w
DeviceTapGeometry
0x02010181.