CameraLink Line Scan Camera
·
User Manual
13
In MVS client software, you can go to Transport Layer Control > Device Tap Geometry to check or
set the tap geometry. The CI Configuration parameter displays the mode that the camera adopts
currently.
Figure 5-3
Device Tap Geometry
For cameras of different models, the mode that the camera supports may differ. Pease refer to the
specification of the camera for details.
5.4 Serial Port Tool
Apart from the MVS client software and frame grabber software, the serial port tool can be used to
detect camera status, read and set its parameters.
You can set camera parameters by connecting CameraLink serial port cable. When accessing the
camera or using the terminal in the application software, you are required to set the parameters as
follows.
Table 5-3
Serial Port Tool
Serial Port Parameter
Value
Baud Rate
9600 bps
Data Bit
8-bit
Parity Bit
None
Stop Bit
1-bit
Stream Control
None