CameraLink Line Scan Camera
·
User Manual
40
RS-644 Standard Output
The camera adopting RS-422 standard output signal cannot directly connect to RS-644 standard.
When connecting RS-644 standard output, it is required to add a resistance network in camera’s
output location. In order to make sure the normal operation of output circuit, it is required to
connect camera’s ground signal with external ground signal.
Figure 8-5
Outputting RS-644 Signal
LVTTL Standard Output
When adopting LVTTL standard as the output signal, the wiring is shown below.
Figure 8-6
Outputting LVTTL Signal