Table 3. RAID Level Reference Table
Type
Descriptio
n
Min.
disks
Usable
space
Advantage
Disadvantage
Application
JBOD
Just a bunch of
disk
1
100%
Each drive can be accessed as a
single volume
No fault tolerance - failure
of one drive results in
complete data loss
Backup
RAID 0
Disk Striping
2
100%
Offers the highest performance
No fault tolerance – failure
of one drive in the array
results in complete data
lose
Temporary file,
performance driven
application.
RAID 1
Disk Mirroring
2
50%
Provides convenient low-cost
data redundancy for smaller
systems and servers
Useable storage space is
50% of total available
capacity. Can handle 1
disk failure.
Operating system, backup,
and transaction database.
RAID
10
Disk Mirroring
followed by
stripe
4
50%
High read performance and
medium write performance with
data protection for up to 2-drive
failures
Useable storage capacity
equals total capacity of all
drives in the array minus
two
Fast database and
application servers which
need performance and data
protection
RAID 5
Disk Striping
with Rotating
parity
3
67-94%
High read performance, and
medium write performance with
data protection with a single
drive failure
Not recommended for
database applications that
require frequent/heavy
write sessions. Can handle
1 disk failure.
Data archives, and ideal
for application that require
data protection
RAID 6
Disk Striping
with dual
rotating parity
4
50-88%
High read performance, and
medium write performance with
data protection in case of up to
two drives failure
Not recommended for
applications that require
frequent/heavy write
sessions.
Data archives and ideal for
application that requires
data protection
Summary of Contents for RocketStor 6314A