Hi-Velocity RBM-100 Installation Manual Download Page 11

www.hi-velocity.com

© 1995-2020 Energy Saving Products Ltd.

© 1995-2020 Energy Saving Products Ltd.

-11-

-11-

Module RBM

RBM Refrigerant Base Module Installation

•  Inoperative parts must be returned to Energy Saving Products Ltd. with an ESP RMA Form that 

includes model, serial number, and a detailed description of the entire problem. Inoperative parts 

must be returned in testable condition.

•  This warranty does not cover shipping costs to and from the factory, labor costs or any other cost 

associated with the installation of the replacement part.

•  Energy Saving Products Ltd. is not liable for any other damages, personal injury, or any other losses 

of any nature.

•  The liability of Energy Saving Products Ltd. is limited to and shall not exceed the cost of pre-approved 

replacement parts.

WARRANTY

A

 

Three (3) Year Limited Warranty

 

is extended on Electric Strip Heaters

.

Five (5) Year Limited Warranty

 

is extended on all components in products manufactured exclusively 

by Energy Saving Products. These components include Motors, WEG Controller, Circuit Boards, Dampers, 
Zoning Controls, Blowers, Motor & Blower Assemblies, Heating Coils, Chilled Water Coils, and Air 
Conditioning Coils.  Note:  If any product is installed in or exposed to a corrosive environment, warranty 
will be void.

 

   

 Energy Saving Products Ltd. is proud to offer a limited warranty. This warranty applies strictly to the first 

purchaser at wholesale level and only to the fan coil unit and module. It does not include connections, attachments 

and other products or materials furnished by the installer.

TERMS & CONDITIONS

•  Any repair performed under warranty must be approved by Energy Saving Products Ltd. for this 

warranty to be valid.

This warranty replaces all other warranties expressed or implied.  

 

www.hi-velocity.com

•  Should there be multiple consecutive failures of a single part, warranty will not be considered unless 

a contractor has contacted Energy Saving Products Ltd. Technical Department for assistance, and 

received a tech code. 

Follow these steps for Service or Repair:

1. 

Contact the installer of the product or a licensed service company                                                                   

2. 

Contact the distributor    

 

 

 

 

 

 

                                        

3. 

Contact Energy Saving Products Ltd.  Mon-Fri  8 am – 4:30 pm MT  1-888-652-2219

     

This warranty excludes any damages caused by changes, relocation to, or installation in a new site. This warranty 

does not cover any defects caused by failure to follow the installation and operating instructions furnished with 

the fan coil. This warranty does not cover defects caused by failing to adhere to local building codes and following 

good industry standards. Failure to correctly install the fan coil, or material related to the unit, may result in 

improper system performance and/or damages and will void this warranty. This warranty does not cover material 

installed in or exposed to a corrosive environment. This warranty does not cover products subjected to abnormal 

use, misuse, improper maintenance, or alteration of the product. Using the fan coil and/or module as a source of 

temporary heating/cooling during construction will void this warranty. 

Products sold by Energy Saving Products but manufactured by others, will carry the original 
manufacturer’s warranty. 

Summary of Contents for RBM-100

Page 1: ...e Installation 052020 RBM Refrigerant Base Module Installation Manual Small Duct High Velocity Heating Cooling and Home Comfort Systems RBM 50 1 5 2 Tons RBM 70 2 5 3 Tons RBM 100 3 5 5 Tons Includes Pre Piped TXV Freeze Stat Service Access Ports T Mounting Brackets Double Sided Mounting Tape Hole Plugs 2 ...

Page 2: ......

Page 3: ...es can be used on any R 410A condenser if R 410A refrigerant components are used All Energy Saving Products R Series modules come standard with R 410A refrigerant components 3 3 The RBM module can be installed as a stand return air base for the fan coil or as a side mounted coil When the desired air inlet side has been determined the module can be adapted The module comes ready as left to up right...

Page 4: ...e unit 90 deg clockwise Fig 07 Fig 07 6 Replace the drain pan in new bottom location Fig 09 Fig 09 Fig 06 3 Slide out the air flow deflector plate Fig 06 Fig 08 5 Slide the air flow deflector plate back into the section it was removed from in the new orientation Fig 08 Fig 10 7 Remove round knock outs on the door to fit drain lines Plug previously used drain holes with provided plugs Fig 10 Insert...

Page 5: ... should always be used to make the first cut For this first cut do not use a saw blade longer than 5 125mm or damage to the coil can occur Return Air Cutouts Mounting Brackets Fig 12 TO AVOID DAMAGE After the first initial cut using the return air knockout s a metal shear must be used to make the return air cutout opening match more closely to the filter or return air ducting size to maximize flow...

Page 6: ...ring needs arise in which the outdoor unit is controlled through another means of wiring the Freeze Stat should be connected in series on the input side of the control wiring Refrigerant Bypass All RBM coils come with a pre installed check valve ready TX valve used for AC only or heat pump condensing units Third party TX valves may require a bypass check valve Fig 14 Bypass check valve 6 6 Freeze ...

Page 7: ...eck local codes Run the proper size copper wires to the unit and connect as per the manufacturer s recommendations Ensure that the unit is setup for a TX system If not a hard start kit may be required Evacuating The system must be brazed under a nitrogen purge to prevent oxidation of the pipe during the brazing process After the piping is installed and all components have been brazed together a va...

Page 8: ...ing brackets are located at the base of the unit for secure mounting The receiver is to be located on the liquid line of the system anywhere between the indoor and outdoor coils As the unit is of a bi flow design it does not matter which end faces towards the indoor coil The inlet outlet ports are constructed of steel and require the use of a 35 45 Silver Solder and Flux for brazing The use of sta...

Page 9: ...HV 70 71 LV 70 HE Z HE P HE B HE HV 100 101 Part Number 41090300050 41090300070 41090300100 Tons 1 1 5 2 0 5 3 7 0 kW 2 5 3 0 8 8 10 6 kW 3 5 5 0 12 3 17 6 kW Refrigerant Type R 410A R 410A R 410A TX Cooling MBH 2 18 24 5 3 7 0 kW 30 36 8 8 10 6 kW 42 60 12 3 17 6 kW Latent Cooling MBH 6 8 8 9 2 0 2 6 kW 11 7 13 7 3 4 4 0 kW 16 0 22 2 4 7 6 5 kW Fin Material Aluminum Aluminum Aluminum Tubing Mater...

Page 10: ...ain Conn Refrigerant Modules B C A D E F RBM 50 14 1 2 368mm 18 1 4 464mm 18 1 4 464mm 3 8 o d 7 8 o d 3 4 M CPVC RBM 70 19 1 2 495mm 18 1 4 464mm 18 1 4 464mm 3 8 o d 7 8 o d 3 4 M CPVC RBM 100 25 1 2 648mm 18 1 4 464mm 18 1 4 464mm 3 8 o d 7 8 o d 3 4 M CPVC RBM Series Sizing A B C D E F 10 10 Module RBM RBM Refrigerant Base Module Installation ...

Page 11: ...and other products or materials furnished by the installer TERMS CONDITIONS Any repair performed under warranty must be approved by Energy Saving Products Ltd for this warranty to be valid This warranty replaces all other warranties expressed or implied www hi velocity com Should there be multiple consecutive failures of a single part warranty will not be considered unless a contractor has contact...

Page 12: ...b Energy Saving Products prides itself on Customer Service and provides design services and contractor support For all of your Heating Cooling and Indoor Air Quality needs the Hi Velocity System is the right choice for you Phone 780 453 2093 Fax 780 453 1932 Toll Free 1 888 652 2219 www hi velocity com Hi Velocity HE Z Fan Coils Hi Velocity HE Z Fan Coils Green Green Technology Technology Build Sm...